DRAIN INSTALLATION
PLEASE READ all instructions completely before attempting to install or operate the unit. All Ice Makers require a connection to the water supply and improper
!CAUTION
Plumbing installation must observe all state and local codes. All water and drain connections MUST BE made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm.
The CLR60 can be installed using a gravity drain or can use a factory installed or equivalent drain pump.
Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and/or potentially flowing onto the floor causing water damage:
Gravity Drain
•Drain lines must have a 5/8 inch inside diameter.
•Drain lines must have a 1 inch drop per 48 inches of run (1/4 inch per foot) and must not create traps.
•The floor drain must be large enough to accommodate drainage from all drains.
•Insulate the bin drain line to prevent condensation.
CLR60 With Factory Installed Drain Pump
NOTE
Before installing your
5