User’s Manual
•Install a
•Connect sufficient tubing to the unit to allow the unit to be moved for cleaning and ser-
vicing. However, make certain that the tubing is not pinched or damaged during installation.
• |
|
copper tubing for installation. | UL005A |
Position the unit to allow free |
|
air flow through the front grille | Figure 3 |
(see Figure 3). |
7.Wipe the inside and outside of the unit with a damp cloth.
CONNECTING THE WATER SUPPLY
1.Remove access panel from front of the unit (see Figure 4).
2.Remove the back panel to ease water line connection.
PANEL
SCREWS
SCREW
PANEL
UL203
Figure 4
3.Install the 1/4 inch copper water line, from the main water source. The water line is inserted through the hole in the rear of the unit, through a clip on the sidewall to connect to the solenoid valve in the front (see Figure 5).
UL204B
Figure 5