User’s Manual

Install a shut-off valve in the 1/4 inch supply line.

Connect sufficient tubing to the unit to allow the unit to be moved for cleaning and ser-

vicing. However, make certain that the tubing is not pinched or damaged during installation.

U-Line specifies the use of

 

copper tubing for installation.

UL005A

Position the unit to allow free

 

air flow through the front grille

Figure 3

(see Figure 3).

7.Wipe the inside and outside of the unit with a damp cloth.

CONNECTING THE WATER SUPPLY

1.Remove access panel from front of the unit (see Figure 4).

2.Remove the back panel to ease water line connection.

PANEL

SCREWS

SCREW

PANEL

UL203

Figure 4

3.Install the 1/4 inch copper water line, from the main water source. The water line is inserted through the hole in the rear of the unit, through a clip on the sidewall to connect to the solenoid valve in the front (see Figure 5).

UL204B

Figure 5

10