User’s Manual

INITIAL START-UP

Once installation and leveling is complete, the unit is ready for initial start-up and operation. Your unit is shipped in the ON position, however, you may turn it ON/OFF using the cycle selector switch located in the grille (Figure 27).

The temperature controller will display even when the cycle selector switch is in the OFF position.

ON

O F F

C L N

ON

O F F

C L N

CYCLE SELECTOR SWITCH

UL316C

Figure 27

1.Plug the appliance cord into a 115V polarized and grounded elec- trical outlet.

2.Make sure the overflow tube (refer to Figures 37 and 38 in Maintenance) is seated properly. There is a possibility it may have loosened during shipment.

3.Make sure the draining system is working properly and the drain hose is not pinched or kinked. Pour one gallon of cool, fresh water into the ice bin. The water should drain freely. If your CLRCO2075 is equipped with a drain pump, the pump should drain the ice bin.

4.Open the water supply valve in the main water source.

5.Be sure that the cycle selector switch is in the ON position. The water fill valve will energize and fill the water reservoir. The water fill valve shuts off after 180 seconds. The compressor begins to oper- ate and water flows over the evaporator assembly (ice cube tray).

6.Upon initial start-up, water flow over the evaporator may be uneven. This may cause uneven sized cubes or water spilling into the ice storage bin. This is a normal situation and will correct itself within the first twenty-four hours of operation. After the initial start- up period, the water will cascade evenly over the evaporator.