After the first slab of ice is produced, ice production will stop until the refrigerator side of the CLRCO2075 reaches the set point tempera- ture. After the refrigerator reaches temperature, ice production will begin again.

It is possible that dirt or scale will dislodge in the water line. Always throw away all ice cubes made during the first two to three hours of operation.

TEMPERATURE CONTROLLER

1 2 3

WARMER

COOLER

SET

TEMP

CLRCO011

Figure 28

The temperature controller (Figure 28) is located below the clear ice maker. It consists of an LED display, three LED status indicator lights and three touchpad buttons. The LED display shows the temperature set point and is calibrated in degrees Fahrenheit. The controller is factory programmed for a set point of 38°F which will show when the unit is first powered up.

To display actual temperature in the refrigerator, press the “WARMER” button momentarily. A solid status indicator light (1, Figure 28) will show and the air temperature reading in the cabinet will show for approximately 10 seconds.

To adjust the temperature set point, press the “SET TEMP” button momentarily; the display will flash. Press the “WARMER” or “COOLER” button as desired to change the set point. When the desired set point shows on the display, wait 10 seconds and the new set point will be saved. Wait 24 hours for the temperature to stabilize before checking the actual temperature again.

23