6 Door Swing Dimensions
All units have a zero clearance for the door to open 90°.
CO29
1/4" Min.
Wall | CLR2160 | Wall |
1/4" Min. |
|
90°
22-3/8"
90 | 90 |
Door Swing | Door Swing |
Black and White | Stainless Steel |
Wall | Wall |
CLRCO2160 | |
1/4" Min. | |
90 | 90 |
Door Swing | Door Swing |
Black and White | Stainless Steel |
Wall | Wall |
CO1175 |
|
1/4" Min. | 2" Min. |
90 | 90 |
Door Swing | Door Swing |
Black | Stainless |
Wall | Wall |
CO2175 |
|
1/4" Min. | |
90 | 90 |
Door Swing | Door Swing |
Black and White | Stainless Steel |
Door Swing
Other Site Requirements
Side-By-Side Installation
For a complete refreshment center, install two units side by side:
No trim kit is required. However,
Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s Electrical Specifications Requirements
Power Supply
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications.
Water Supply
The unit requires a 1/4” O.D. soft copper supply line, or flexible water supply kit from
Drain
The CLR2160 & CLRCO2175 require access to either a gravity or pump fed drain.
Environmental Requirements
The units are designed to operate between 50°F (10°C) and 100°F (37°C). High ambient temperatures (100°F [37°C] or higher) may reduce the unit’s ability to reach low temperatures and may also reduce the ice production rate for those models with ice makers.
If the ambient temperature is expected to drop below 45°F (7°C), drain all water from the unit to prevent freezing damage, which is not covered by the warranty.
For best performance, keep the unit out of direct sunlight and away from heat generating equipment.
For best performance and life outdoors, place under a counter or provide shelter of some kind.
In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal. The condensation will evaporate when the humidity drops.