10Prepare Power Supply

Electrical Specifications

WARNING

SHOCK HAZARD — Electrical Grounding Required.

Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.

Never use an extension cord to connect power to the unit.

IMPORTANT

Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three- prong), polarized receptacle that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes.

See below for recommended receptacle location

CLR2160 & CLRCO2175

Preferred

 

Location

Acceptable

for CLR2160

Receptacle

Location

24"

7"

1"

CO29

24"

7"

1-1/2"

CO1175

7"

4"

CO29

7"

1-1/2"

CO2175FF

7"

1-1/2"

24"

24"

Minimum

24"

U-Line Electrical / Plumbing Specfications

11

Page 13
Image 13