Condenser Cleaning

Interval - Every Three Months

To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.

WARNING

Disconnect electric power to the unit before cleaning the condenser.

WARNING

DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.

IMPORTANT

DO NOT use any type of cleaner on the condenser unit.

1. Disconnect power to the unit.

2

1

ULIN_0197_A

Figure 7

2.Remove the control knob (Figure 7, 1) by pulling it straight out, away from grille.

3.Remove two screws from grille (Figure 7, 2) and save.

4.Remove grille and grille cap from unit.

1

ULIN_0153_A

Figure 8

5.Clean the condenser coil (Figure 8, 1) using a using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.

 

2

1

ULIN_0198_A

Figure 9

6.Make sure grille cap is behind grille in slots provided in grille (Figure 9, 1) before attaching grille to unit, and secure but do not overtighten both grille screws (Figure 9, 2).

7.Reinstall the control knob (Figure 7, 1).

8.Reconnect power to the unit.

Ice Maker Maintenance

Inlet Screen

Interval - Every Twelve Months

The solenoid valve inlet screen must be cleaned at least once each year as follows:

1.Shut off the water at the main supply valve.

2.Pull the unit out to access the back panel.

3.Disconnect electrical power to the unit.

2

1

ULIN_0054_A

Figure 10

4.Disconnect the hose connector (Figure 10, 1) from the water solenoid valve (Figure 10, 2).

5.DO NOT remove the inlet screen from the water solenoid valve. Use a tooth brush to gently clean any sediment from the inlet screen.

6.Re-connect the water supply hose connector (Figure 10, 1) to the water solenoid valve (Figure 10, 2). Tighten the connector securely.

7.Open the water main supply valve and check for leakage at the water hose connection. Ensure that the water supply line is not kinked.

8.Reconnect power to the unit before re-installing.

10

CO29FF

Page 10
Image 10
U-Line CO29FF manual Condenser Cleaning, Ice Maker Maintenance, Interval Every Three Months