![Ice Maker Maintenance](/images/new-backgrounds/49842/4984221x1.webp)
6.Insert the grille screw (Figure 8, 1) and tighten. Do not
7.Reconnect power to the unit.
Ice Maker Maintenance
Inlet Screen
Interval - Every Twelve Months
The solenoid valve inlet screen must be cleaned at least once each year as follows:
WARNING
Disconnect electrical power to the unit before cleaning the solenoid valve.
Models 95 and 98
1.Disconnect electrical power to the unit.
2.Shut off the water at the main supply valve.
1
ULIN_0238_A
Figure 9
3.With a standard blade screwdriver or 1/4" nut driver, remove the grille screw (Figure 9, 1).
4.Remove the grille.
WARNING
DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.
2
1
ULIN_0064_A
Figure 10
5.Disconnect the hose connector (Figure 10, 1) from the water solenoid valve (Figure 10, 2).
6.DO NOT remove the inlet screen from the water solenoid valve. Use a toothbrush to gently clean any sediment from the inlet screen.
7.
8.Open the water main supply valve and check for leaks at the water hose connection. Ensure that the water supply line is not kinked.
9.Place the two
10.Insert the grille screw (Figure 9, 1) and tighten. Do not
11.Reconnect power to the unit.
Model SP18
1.Disconnect electrical power to the unit.
2.Shut off the water at the main supply valve.
3.Pull the unit out to access the back panel.
2
1
ULIN_0065_A
Figure 11
4.Disconnect the hose connector (Figure 11, 1) from the water solenoid valve (Figure 11, 2).
5.DO NOT remove the inlet screen from the water solenoid valve. Use a toothbrush to gently clean any sediment from the inlet screen.
6.
7.Open the water main supply valve and check for leaks at the water hose connection. Ensure that the water supply line is not kinked.
8.Reconnect power to the unit before
BI95, BI98, SP18 | 11 |