U-Line U-CO29F, SP 18 Frost Free Refrigeration, Service and Repair, Cooling Mode, Defrost Mode

Models: ULN-SS1095 ADA15IM ULN-29R U-CO1175 BI-2115 ULN-95 U-CO29F ULN-98 U-CO29A U-1075WC U-1075BEV SP 18

1 66
Download 66 pages 37.32 Kb
Page 17
Image 17
Frost Free Refrigeration

Section 3 - Service and Repair

Frost Free Refrigeration

COOLING MODE

Bypass solenoid closed.

Evaporator fan operating.

Refrigerant flows through capillary tubes.

Normal vapor/compression cycle refrigeration (see page 3- 1).

DEFROST MODE

Bypass solenoid valve open.

Refrigerant flows through bypass system.

Vapor flows from condenser to evaporator without a phase change.

Drain heater on (U-CO29F only).

 

COMPRESSOR

 

CONDENSER

 

 

DRYER

 

EVAPORATOR

 

FLOW WHEN SOLENOID

 

 

VALVE IS CLOSED

 

 

CAPILLARY TUBE

 

 

 

FLOW WHEN SOLENOID

 

 

VALVE IS OPEN

 

SOLENOID VALVE

ULIN_0369_A

 

 

 

Figure 2. Frost Free Refrigeration System.

 

 

 