U-Line SP 18 Ice Maker Diagnosis Flow Chart, Intermittent, Troubleshooting, Low Voltage, 12:00AT

Models: ULN-SS1095 ADA15IM ULN-29R U-CO1175 BI-2115 ULN-95 U-CO29F ULN-98 U-CO29A U-1075WC U-1075BEV SP 18

1 66
Download 66 pages 37.32 Kb
Page 12
Image 12
ICE MAKER DIAGNOSIS FLOW CHART

Section 2 - Troubleshooting

ICE MAKER DIAGNOSIS FLOW CHART

INTERMITTENT Sealed System Leak

Low Voltage Electrical Failure

12:00AT Compressor Failure

3:00 Fan Motor Failure

Manual background Defrost System Failure

DOES THE UNIT REFRIGERATE?

NO

 

INTERMITTENT

 

 

 

YES

Low Voltage

 

 

Manual background Voltage Drop

Manual background Wiring

DOES THE UNIT HARVEST ICE

IF THE EJECTOR BLADES ARE

MOVED BY HAND OR WITH A

WRENCH ?

 

YES

NO

 

 

 

 

Temperature Control Failure

 

 

Water Adjustment

 

 

 

Bin Switch Failure

WHERE DO THE

 

 

 

 

EJECTOR BLADES

 

 

EVERYWHERE

STOP?

AT

 

 

 

 

12:00AT

3:00

Ice Motor Failure

 

 

Hold Switch Failure

Limit Switch Failure

Binding Cam/Ejector

IS THERE VOLTAGE AT THE

SOLENOID VALVE TERMINALS

DURING HARVEST?

Manual background Mold Heater Failure

NO

YES

Water Switch Failure

Solenoid Valve Failure

 

UL183-11

2-3

Page 12
Image 12
U-Line SP 18, U-1075BEV, U-1075WC Ice Maker Diagnosis Flow Chart, Intermittent, Troubleshooting, Low Voltage, 12:00AT