Section 3 - Service and Repair

TEMPERATURE CONTROL

SPECIFICATIONS

Double Throw Ice Maker Thermostat Numbers 4548, AR-19-12, 2636, 2690, 2691, 2717, 2783, 2782, 2781, 2780

These temperature controls are double throw, single pole controls. The sensing tube is inserted into the ice maker mold

and senses mold temperature. After ice is sensed in the mold, the 2-3 contacts open (stopping the compressor) and the 2-1 contacts are closed (starting the ice maker motor). The 2-3 contacts close (2-1 contacts open) before the end of the ice harvest cycle.The hold switch prevents power going back to the compressor. This prepares the control for the next cycle

.

 

 

 

RED WIRE

YELLOW WIRE

 

1

CONNECTION

CONNECTION

2

 

 

 

 

 

 

3

 

 

 

 

BLUE/BLACK WIRE

 

ICE MAKER CONTROL

CONNECTION

 

 

 

183-8

2

1

 

1

2

 

 

 

3

 

3

FREEZE POSITION

ICE HARVEST POSITION

CYCLE

OPEN

 

CLOSED

CIRCUIT

 

CIRCUIT

 

 

FREEZE

2 - 1

 

2 - 3

HARVEST

2 - 3

 

2 - 1

 

 

 

183-9

Figure 11. Temperature Controls - Manual Defrost Ice Makers

3-9

Page 24
Image 24
U-Line SP 18, U-1075BEV, U-1075WC, ULN-98 Temperature Control Specifications, Temperature Controls Manual Defrost Ice Makers