U-Line U-2175BEVCOL-60 Air Flow, Initial Startup, Electronic Control Panel, Product Operation

Models: U-2115RB-00 U-2175BEVCS-02 U-2115WCS-00 U-2115WCOL-00 U-2175BEVCOL-00 U-2175BEVCOL-02 U-2175WCCOL-00 U-2175WCCS-02 U-2175BEVCOL-60 U-2175WCCS-13 U-2175BEVCS-00 U-2175WCCOL-02 U-2175WCCOL-60 U-2175WCCS-22 U-2175WCCS-00

1 28
Download 28 pages 41.87 Kb
Page 6
Image 6
3 Product Operation

3 Product Operation

Air Flow

IMPORTANT

The unit requires proper air flow to perform at its highest efficiency. Do not block the front grille or internal fans at any time, or the unit will not perform as expected. Do not install the unit behind a door.

Initial Startup

All U-Line controls are preset at the factory. Initial startup requires no adjustments.

IMPORTANT

U-Line recommends allowing the unit to run overnight before loading refrigerator or freezer with product.

To turn the unit on or off, press and hold POWER (1) for about ten seconds and release. The display will show the unit set-point temperature when turned on and display OFF when the unit is off.

Electronic Control Panel

Digital Display.

The electronic control with digital display shows a single continuous set-point temperature. The factory default set-point for Glass Door Refrigerators and Refrigerator models is 38°F. The factory default set-point for Wine Captain® models is 50°F. The set-point temperature is a gauge for further temperature adjustments.

Turning the Display Off. Wine Captain® Models and Glass Door Refrigerators have a DISPLAY OFF mode available through the control panel. This allows you to control if the display will be ON or OFF with the door closed. The icon sequence that follows will switch between both modes, On or Off:

1.Press and hold WARMER (2), and simultaneously within five seconds press POWER (1) three times.

2.The display will be either visible or dark with the door closed. To return to the previous mode, repeat Step 1.

Adjusting Air Temperature

IMPORTANT

Adjust the set point temperature in single increments, and wait 24 hours for the temperature to stabilize before rechecking.

1

2

3

4

5

To adjust the set point temperature:

1.Press and release either WARMER (2) or COOLER (4) to put the controller in the SET TEMPERATURE mode. The display

(3)will begin to flash the °F (or °C) symbol.

NOTE: This mode will self-cancel in five seconds, and the display (3) will show the original set-point temperature.

2.Within five seconds (while the °F (or °C) symbol is flashing), press WARMER or COOLER as required to adjust the set point temperature.

3.The change is committed five seconds after adjusting the temperature, and the display (3) will show the new set-point temperature.

Temperature °F °C Selection. U-Line products supplied for 110 VAC have temperatures displayed (3) default in Fahrenheit (°F). Models supplied for 220 VAC have temperatures displayed (3) default in Celsius (°C).

Easily adjust the display for either type temperature display.

Press and hold LIGHT (1) and simultaneously within five seconds press COOLER (5) three times to change the display

(3) as needed.

Temperature Display. The digital display shows set-point. Under normal operating conditions the temperatures will fluctuate based on a number of factors including door openings, product load, room temperature, and humidity. On passive cooled units the temperature will always be coolest toward the bottom.

To display actual temperature:

1.Press WARMER (2) for five seconds. The display (3) will indicate the actual temperature.

2.After about 10 seconds, the set point temperature will return to the display.

3

U-Line Product Operation

Page 6
Image 6
U-Line U-2175BEVCOL-60 Air Flow, Initial Startup, Electronic Control Panel, Adjusting Air Temperature, Product Operation