5 Maintenance

5 Maintenance

Light bulb Replacement

To replace the light bulb in your U-Line unit:

1.Find the light located at the top of the unit. Grasp the edges of the light housing lens (1) opposite the exposed tab and gently push the lens toward the tab (2).

2.Pull the edge of the lens down (1) and swing it out of the light housing.

For Models without adjustable leveling feet:

IMPORTANT

The unit must be located on a level surface, for proper door and ice maker (if equipped) operation.

1.Use a level to check the levelness of the unit from front to back and from side to side. Place the level along top edge and side edge as shown (1).

 

2

Removing and Installing Interior Shelves

1

 

 

 

IMPORTANT

ALWAYS use a genuine U-Line replacement 120V 10 watt bulb (Part Number 31317) in the light housing. Use of any other bulb within the housing will produce excessive heat, causing damage to the light housing and cabinet interior, and will compromise the precise temperature control of the unit.

1.Replace the lens by first inserting the tab side back into the housing at a slight angle.

2.While gently pushing the lens towards the tab end, push the free end into the housing, and release when you hear a snap.

Leveling

IMPORTANT

Unit must be level, for proper door and ice maker (if equipped) operation.

For Models with adjustable leveling feet:

1.

Use a level to check the

 

 

levelness of the unit from front

 

 

to back and from side to side.

 

 

Place the level along top edge

 

 

and side edge as shown (1).

 

2.

If the unit is not level, rotate

 

 

the adjustable leveling legs to

 

 

raise or lower each corner of

 

 

the unit (5) as necessary.

1

 

 

3.

Check levelness after each

 

 

adjustment and repeat the

 

 

previous steps until the unit is

 

 

level.

 

3

1

2

For models equipped with glass shelves having recessed shelf supports, remove the shelves as follows:

1.Pull shelf out about 6" (1), until back of shelf clears the “hump” on the right-hand side.

2.Tilt up right-hand edge of shelf (2).

3.Remove shelf from unit by pulling out (3).

Insert the shelves as follows:

1.To move to a different position in the unit, insert shelf at an angle, approximately 15-20°, over the rib in the side of the unit where you want to place the shelf. Place the shelf into the unit at an angle to clear the door.

2.Continue to slide the shelf into the unit at an angle until it clears the door.

3.Lower the shelf and push it in completely. Ensure the raised edge strip is toward the rear of the unit and the decorative graphics, if applied, are on the underside of the shelves.

IMPORTANT

Make sure the shelves are inserted fully into the unit.

The edge strip toward the rear prevents cans and bottles from freezing against the cold evaporator.