WARNING

MOVING PARTS HAZARD

Moving parts can pinch or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not alter or modify equipment.

For professional use only.

Use equipment only for its intended purpose. Call your Graco distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not use hoses to pull equipment.

Comply with all applicable safety regulations.

PRESSURIZED ALUMINUM PARTS HAZARD

Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment. Such use can cause serious chemical reaction and equipment rupture, and result in death, serious injury, and property damage.

SUCTION HAZARD

Never place hands near the pump fluid inlet when pump is operating or pressurized. Powerful suction could cause serious injury.

CARBON MONOXIDE HAZARD

Exhaust contains poisonous carbon monoxide, which is colorless and odorless. Breathing carbon monoxide can cause death. Do not operate in an enclosed area.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.

Read MSDS’s to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

BURN HAZARD

Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely.

PERSONAL PROTECTIVE EQUIPMENT

You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to:

Protective eyewear

Clothing and respirator as recommended by the fluid and solvent manufacturer

Gloves

Hearing protection

4

311797B

Page 4
Image 4
Uniden GH 230 Moving Parts Hazard, Equipment Misuse Hazard, Pressurized Aluminum Parts Hazard, Suction Hazard, Burn Hazard

GH 300, GH 130, GH 200, GH 230 specifications

Uniden is a well-known brand in the realm of communication devices, and their GH series offers an array of headsets that combine cutting-edge technology with user-friendly features. The GH 200, GH 300, GH 130, and GH 230 are notable models that cater to diverse user needs, offering excellent sound quality, comfort, and robust connectivity.

The Uniden GH 200 is designed for those who prioritize comfort and clarity. It features a lightweight build with cushioned ear pads, ensuring extended wear without discomfort. This model boasts advanced noise-cancellation technology, which effectively minimizes background noise to enhance audio quality during calls. The GH 200 also supports Bluetooth connectivity, allowing users to connect seamlessly with smartphones and other devices, making it a versatile choice for both personal and professional use.

Moving up the line, the Uniden GH 300 provides a more advanced feature set. In addition to superior audio quality and noise-cancellation capabilities, the GH 300 comes with a long-lasting battery life, offering several hours of operation on a single charge. This model is equipped with intuitive touch controls, allowing users to easily manage calls and music playback without fumbling with their connected device. With its sturdy construction and sleek design, the GH 300 is a durable option suitable for various environments, from office settings to outdoor activities.

The Uniden GH 130 is tailored for users seeking a budget-friendly yet functional headset. It includes essential features such as clear sound and a comfortable fit. Although it may not have all the bells and whistles of its pricier counterparts, the GH 130 still delivers a reliable performance for everyday use. This model is particularly popular among students and professionals who need a straightforward communication tool without compromising on quality.

Finally, the Uniden GH 230 strikes a balance between performance and affordability. It incorporates a mix of the standout features found in both the GH 200 and GH 300, offering good audio clarity along with moderate noise-cancellation capabilities. The GH 230 is equipped with adjustable headbands and a flexible microphone, catering to users who appreciate customizability. This model also supports both wired and wireless connectivity, providing versatility in connection options.

In conclusion, the Uniden GH series, encompassing the GH 200, GH 300, GH 130, and GH 230, offers a variety of headsets that meet the needs of different users. With a combination of comfort, audio quality, and innovative technologies, each model presents unique features tailored to enhance the communication experience.