Uniden GH 130, GH 230, GH 200 Hydraulic Motor Rebuild, Flying Parts Hazard, Removal, Installation

Models: GH 300 GH 130 GH 200 GH 230

1 34
Download 34 pages 15.88 Kb
Page 14
Image 14
Hydraulic Motor Rebuild

Hydraulic Motor Rebuild

Hydraulic Motor Rebuild

(Figure 5)

Removal

1.Relieve pressure, page 7.

2.Place drip pan or rags under sprayer to catch hydraulic oil that leaks out during repair.

3.GH130 Models:

- Follow Steps 2-5 of pump removal instructions, page 17.

GH200, GH230, GH300 Models:

-Follow Steps 4-8 of pump removal instructions, page 18.

4.Remove hydraulic lines (271, 288) from fittings (266) at top left and right side of hydraulic motor.

5.Loosen jam nut (264).

6.Unscrew and remove hydraulic motor cap (265).

7.Slide piston rod/hydraulic motor cap assembly (A) from hydraulic motor cylinder (263).

8.Remove yoke (257).

a.Clamp hydraulic motor cap (265) in vise with hydraulic motor piston rod facing up.

b.Use shortened Allen wrench to remove two screws

(260)from spring retainer (261). Remove yoke, spring retainer, piston and trip rod assembly from hydraulic motor cap.

FLYING PARTS HAZARD

Detent spring has high energy potential. If detent spring is released without due care detent spring and balls could fly into the eyes of the disassembler. Wear safety glasses when removing or installing detent spring and balls. Failure to wear safety glasses when removing detent spring could result in eye injury or blindness.

9.Cover spring retainer (261) with a rag to contain detent spring (258) and balls (259) when they are removed from

yoke. Remove detent balls and spring. Remove spring retainer.

10.Put yoke in vise and remove piston rod assembly from yoke.

Installation

FLYING PARTS HAZARD

1.Put hydraulic motor cap (265) in vise.

2.Install yoke (257), spring retainer (261), piston and trip rod assembly in hydraulic motor cap (265). Use shortened Allen wrench to install two screws (260) in spring retainer to secure piston rod assembly to hydraulic motor cap.

3.Slide piston rod assembly into hydraulic motor cylinder (263).

4.Screw down hydraulic motor cap (265). Unscrew hydraulic motor cap until inlet and outlet align with hydraulic line fittings and test hole in hydraulic motor cap points toward belt guard (117).

5.Torque jam nut (264) against hydraulic motor cap (265) to 150 ft-lb (17 N·m).

6.Fig. 5. Install hydraulic lines (271, 288) to fittings (266) to top left and right side of hydraulic motor; torque to 40 ft-lb (54.2 N·m).

7.GH130 Models:

- Follow Step 2 of pump installation instructions, page 17.

GH200, GH230, GH300 Models:

- Follow Steps 2-7 of pump installation instructions, page 19.

8.Start engine and operate pump for 30 seconds. Turn engine OFF. Check hydraulic oil level and fill with Graco hydraulic oil, page 6.

14

311797B

Page 14
Image 14
Uniden GH 130 Hydraulic Motor Rebuild, Flying Parts Hazard, Removal, Installation, Relieve pressure, page, 3. GH130 Models