Unigreen P500 Calibrating Turbo Teuton, where, = volume to distribute L/ha, = tractor speed Km/h

Models: P400 P300 P500 P600

1 36
Download 36 pages 40.67 Kb
Page 21
Image 21
6.3CALIBRATING TURBO TEUTON

6.3CALIBRATING TURBO TEUTON

The tables on pages 26-31 let you easily calculate the distribution in litres/ hectare of the mistblowers with the standard fittings, proceeding as indicated below:

a)Choose the table relevant to the blower group of the mistblower in question (the main reference is the number of jets)

b)Find the distance between the rows of the vegetation and the diameter of the nozzles used (ceramic plates, TR or TXA).

c)In the horizontal strip, choose the working speed and the distribution in litres/hectare and on the vertical scale find the pressure to use.

d)Adjust the pressure to obtain the treatment required.

If the distance between the rows is different from that in the table you can easily calculate the distribution in proportion: for example with a distance between the rows of 8 m, divide the figure for the litres/hectare of the distance between the 4 m rows by half, with a distance between the rows of 2.5 m double the figure for the distance between the 5 m rows.

The last line of the table indicates the overall delivery of the fan.

If the mistblower is fitted with non-standard nozzles, the spraying tables of the single nozzles per mistblower are on page 32.

To calculate the distribution in litres/hectare, use the following formula:

Vd = 600 x Q

 

 

 

 

 

 

 

 

I x V

where:

Vd

= volume to distribute (L/ha)

 

 

 

Q

= sum of the nozzles delivery (L/min)

 

 

 

I

= distance between the rows (m)

 

 

 

V

= tractor speed (Km/h)

EXAMPLE:

Distance between the rows: 5 m

Speed: 6 Km. / h

Working air pressure 30 bar

Fan Ø 800 with 14 standard, high volume nozzles (Ø 1.0)

Q total delivery of the nozzles (Tab. 1 page 34) 2.96x14= 41.44 L/min

Vd = 600 x 41.44 = 829 L/ha 5 x 6

N.B. : Depending on the season the vegetation may be more or less luxuriant; bear this in mind before starting the treatment. If the plants don’t have much foliage you should diminish the quantity of litres per hectare using lower pressures or closing one or more jets of the fan.

N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width.

Example-

In the table: 907lt/ha with row distance 3m.

907x3 = 971 Lt/ha with row distance 2,8m

2,8

unigreen 21

Page 21
Image 21
Unigreen P500, P600, P300 Calibrating Turbo Teuton, where, = volume to distribute L/ha, = sum of the nozzles delivery L/min