TROUBLESHOOTING

DESCRIPTION

POSSIBLE PROBLEM

SUGGESTED REMEDY

 

 

 

 

 

 

Gas supply off

Check main / unit gas valves

 

 

 

 

 

 

Air in lines

Turn gas valve on. Attempt to light

 

Pilot will not light

pilot every 15 sec.

 

 

 

 

 

 

 

 

Pilot valve not on or not depressed

Refer to page 10 for pilot lighting

 

 

instructions

 

 

 

 

 

 

 

 

 

 

Turn off gas — allow unit to

 

 

Pilot light not lit

vent for 5 minutes. Turn gas back on

 

Burners won’t light

 

and light pilot

 

 

Control not on

Turn temperature control to desired

 

 

temperature

 

 

 

 

 

 

 

 

 

Water in burner

Remove burner and dry

 

Individual burner won’t

thoroughly

 

light

Damaged temperature control,

Contact Authorized Wells

 

 

burner or other internal component

Service Agency for repairs

 

 

Temperature control not set

Adjust for desired temperature

 

 

 

 

 

Burner not hot enough

Shutter or nozzle out of adjustment

Contact qualified technician for

 

adjustment

 

 

 

 

 

 

 

 

 

Damaged temperature control,

Contact Authorized Wells

 

 

element or other internal component

Service Agency for repairs

 

 

Grease drawer full or not installed

Empty grease drawer.

 

 

Install properly

 

Griddle drips grease

 

 

Damaged internal component

Contact Wells Authorized Service

 

 

 

 

Agency for repairs

 

 

 

 

 

 

 

 

 

NOTE: There are no user serviceable components in the griddle. In all

 

 

cases of damage or malfunction, contact your Authorized Wells Service

121

 

Agency for repairs.

 

 

 

p/n 45324 OpManual Countertop Gas Griddles

 

 

 

 

 

 

14

Page 16
Image 16
United States Pumice Company WG-2424G, WG-3036G, WG-2436G Troubleshooting, Description Possible Problem Suggested Remedy