OPERATING INSTRUCTIONS
Your Hotblast Furnace is for burning wood only.
WOOD BURNING: (1)use Hardwood, 18" to 26", split and air dried (seasoned) for six months. (2) set thermostat to "HIGH" before opening feed door. (3) add wood to a convenient level.
CAUTION
DO NOT OPERATE WITH THE FEED AND/OR ASH DOOR OPEN. THIS FURNACE IS DESIGNED FOR THER- MOSTATIC OPERATION. OPERATION WITH ANY OF THESE DOORS OPEN WILL OVERHEAT AND DAMAGE THE FURNACE.
CAUTION
NEVER USE GASOLINE,
CAUTION
NEVER STORE FLAMMABLE LIQUIDS, ESPECIALLY GASOLINE, IN THE VICINITY OF THE FURNACE.
ADJUSTING BLOWER LIMIT CONTROL SETTINGS
The temperature in the plenum of the warm air furnace at which the blower turns on or turns off, is controlled by the setting of the pointers in the blower limit control (See Fig. 12). These pointers may be adjusted through their entire range of settings to achieve the desired warm air output from the furnace. (See Fig. 16 Below)
1.Move both pointers towards the right (counter clock- wise) - this increases the temperature setting at which the blower will turn on and off.
2.Move both pointers towards the left (clockwise) - this decreases the temperature setting at which the blower will turn on and off.
3.Move pointers away or apart from each other- this increases the time that the blower will run on each warm cycle.
BLOWER FAN
"OFF" POINTER
BLOWER FAN "ON" POINTER
BLOWER LIMIT
POINTER AND STOP
FIG. 16
•DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• | 17 |