BLOWER & COMPONENT ASSEMBLY - FIG. 11
1.Attach the Honeywell Limit Control to the bracket as shown below, using (2) of the #12 x 3/4" Tek Screws provided in the parts bag.
2.Attach the 2x4 Junction Box to the bracket. Use (2) of the #12 x 3/4" Tek Screws provided. Also, attach the flexible conduit from the Limit Control to the junction box using one of the Romax Conduit fitting and red
3.Unbox the blower and attach to the unit by sliding the flange on the blower between the cabinet back and the unit bottom.
4.Now attach the blower to the unit by lining up the two holes and mounting blower with (2)
5.Attach the conduit from the blower to the junction box using one of the Romax Conduit fitting and red
6.Run the wires from the house supply into the junction box. Use the Romax Cable Clamp and red anti- short bushing provided.
7.Wire the components as shown in the wiring diagram on page 12.
8.Replace junction box cover.
LIMIT CONTROL MOUNTING BRACKET
CONDUIT
JUNCTION BOX MOUNTING BRACKET
1
2
3
5
4 | CONDUIT TWISTS INTO |
| MOTOR HOUSING |
•DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• | 11 |