Locating the Furnace

1. The furnace should be located in the

 

same room as the central system

 

and as close as possible, but no

 

closer than 9". There should be no

 

wall between the furnace and the

 

warm air outlet duct that is con-

 

nected directly to the warm air outlet

18"

plenum of the central furnace. See

 

Fig. 2.

 

2. The unit will require installation with

6" SOLID DAMPER

 

the following clearances:

 

Unit to sidewall . . . . . .12" (305 mm)

6" BAROMETRIC

Unit to backwall . . . . . 30" (760 mm)

DRAFT REGULATOR

Chimney connector pipe to sidewall

(OPTIONAL)

. . . . . . . . . . . . . . . . . . 21" (530 mm)

18"

Chimney connector pipe to backwall

 

. . . . . . . . . . . . . . . . . . 18" (460 mm)

 

Hot air ducts to combustibles

 

. . . . . . . . . . . . . . . . . . . 6" (150 mm)

 

NOTE: Install only on a noncom-

 

bustible floor.

 

(REFER TO FIG. 2 & 3)

 

3. Place the furnace on a noncombus-

 

tible floor.

 

4.Check figures 2 and 3. Be sure you have the clearances shown from the furnace and the connector pipe to combustible surfaces. If you have a solid brick or stone wall behind your heater, you can place the furnace as close as you wish to the wall. If the wall is only faced with brick or stone, treat it as a combustible wall.