Lennox International Inc LZP-2 Troubleshooting, Detecting Hvac System Problems, Symptom

Models: Zone Control Panel LZP-2

1 12
Download 12 pages 34.31 Kb
Page 10
Image 10
Troubleshooting

Troubleshooting

DETECTING HVAC SYSTEM PROBLEMS

 

 

Symptom

Possible Solution

 

 

 

Pressure switch open.

 

Consult condensing unit manual for possible cause.

 

 

 

Compressor is off due to internal overload protector.

Condensing unit receiving signal but will not turn on.

Consult condensing unit manual for possible cause.

 

Condenser control board anti short cycle timer is not

 

 

yet expired. Most anti short cycle timers are 5 minutes

 

or less, if the unit does not start after 5 minutes consult

 

the condensing unit manual for possible causes.

 

 

 

A high static condition exists. Move the sensor

 

further down stream to sense air that has mixed more

 

thoroughly. Be sure not to place the senor past

Furnace tripped the primary limit, but the

the take offs. High static pressure must be corrected.

 

zone panel does not indicate that the discharge

Bypass tap is too close to inlet of air handler.

air limit has been exceeded.

Adjust bypass tap in the return air duct so that is further

 

 

away from the furnace. This will give the air more of a

 

chance to be tempered with room return air before

 

entering the air handler again.

 

 

 

Limit on furnace open. Check position of DAS in

 

the plenum and move further down stream if possible.

 

High static condition must be corrected.

Air handler receiving signal but will not turn on.

 

DAS limit jumper needs to be moved to a lower setting.

 

 

 

 

Trouble shoot air handler – see air handler

 

documentation.

 

 

Page 10

Page 10
Image 10
Lennox International Inc LZP-2 Troubleshooting, Detecting Hvac System Problems, Symptom, Possible Solution