United States Stove 1357M, 1557M owner manual Locating the Furnace, Figure

Models: 1357M 1557M

1 28
Download 28 pages 47.62 Kb
Page 7
Image 7
Locating the Furnace

Locating the Furnace

1.The furnace should be located in the same room as the central system and as close as possible, but not closer than 9". There should be no wall between the furnace and the warm air outlet duct that is connected directly to the warm air outlet plenum of the central furnace. (See Fig. 4)

2.Place the furnace on a noncombustible floor.

3.Check figures 3 through 5. Be sure you have the clearances shown below from the furnace and the connector pipe to combustible sur- faces. If you have a solid brick or stone wall behind your furnace, you can place the furnace as close as you wish to the wall. If the wall is only faced with brick or stone, treat it as a combustible wall.

18"

6" CHIMNEY

21"

12"

CENTRAL

FURNACE

 

 

9"

48"

Figure 4

 

 

1357M

1557M

18"

Unit to Sidewall

12"

12"

 

(305mm)

(305mm)

 

Unit to Backwall

30"

30"

6" SOLID DAMPER

(760mm)

(760mm)

 

Front of Unit to

48"

48"

6" BAROMETRIC

Combustible

(1.22m)

(1.22m)

DRAFT REGULATOR

Chimney Pipe

18"

21"

 

to Sidewall

(460mm)

(530mm)

 

Chimney Pipe

18"

18"

18"

to Backwall

(460mm)

(460mm)

 

Plenum to

6"

6"

 

Combustibles

(150mm)

(150mm)

 

PLENUM

 

 

 

TO

6" MIN.

 

 

 

CEILING

 

 

2" MIN. AIR SPACE

 

 

 

 

 

 

 

 

REQUIRED BY CODE

 

 

 

 

 

NON-COMBUSTIBLE FLOOR

Figure 5

CENTRAL

FURNACE

Figure 3

7

Page 7
Image 7
United States Stove 1357M, 1557M owner manual Locating the Furnace, Figure