DELUXE FILTER BOX KIT #C61999
Model 1600 / 1800 (see service bulletin #2)
16" x 20" x 1" Filter Required
1. Attach sides of filter box to bottom with
(4) sheet metal screws per side.
Be sure sides are inside bottom lips and positioned with predrilled holes as illustrated.
Side with no
lip faces back of furnace.
2" Lip
2.Position top so 2" wide lip is turned toward furnace. Place top over sides and secure with (4) sheet metal screws per side.
3.Center assembly from left to right on back of furnace with bottom of filter box resting on edge of furnace bottom.
Be sure filter box is perfectly square. Mark position of screw holes on back of furnace. Drill starter holes and secure assembly to back of furnace with
NOTE: DO NOT PLACE A SCREW IN THE MIDDLE HOLE
OF EITHER SIDE AT THIS POINT.
4. Attach filter holders to sides of enclosure with sheet metal
screws. | 16" x 20" opening |
|
5.Position filter filler between side filter holders and secure to back of furnace with two
6. Attach blower access cover to enclosure with sheet metal screws.
Insert filter (not supplied).
7.Attach handle to filter cover and slide into position.
8.Connect cold air return
duct to top flange of filter box.
NOTE: Drill, punch, or cut access holes as necessary for entrance of power cables, thermostat wire and domestic hot water coil
27