United States Stove 2941 F36 BLOWER KIT, Tools And Material Needed, Circulator Dimensions

Models: 2941

1 10
Download 10 pages 63.55 Kb
Page 2
Image 2
TOOLS AND MATERIAL NEEDED

TOOLS AND MATERIAL NEEDED

TOOLS

MATERIALS

Pencil

Chimney Connection- 6" Dia. Black

6 Foot Folding rule or tape

Steel (24 Ga. minimum): Straight or

Tin Snips

corrugated elbow (as required)*

Drill, hand or electric

1/2" Sheet Metal Screws

Drill bit, 1/8" dia.

6" Inside Diameter Underwriters

(for sheet metal screws)

Laboratories (UL) listed Residential

Gloves

Type and Building Heating Appliance

Screwdriver (blade-type)

Chimney, Type "HT", or 6" existing

5/16" Nut Driver or

Masonry Chimney with flue liner.

5/16" Socket w/Ratchet

Floor Protector Material: 3' x 4'-6" as

 

specified on page 4.

 

Furnace Cement (Manufacturer

 

recommends: Rutland Code 78 or

 

Equivalent)

 

* Avoid adjustable elbows, they leak!

CIRCULATOR DIMENSIONS

Fig. 1

 

32 1/4

19 1/4

4 1/4

12 1/2

CENTER LINE OF 6"

 

CENTER LINE

 

CHIMNEY CONNECTOR

 

 

 

OF 6"

 

 

 

 

 

 

CHIMNEY

 

WONDERWOOD

 

CONNECTOR

33 1/2

24

4 1/8

TOP OF FLOOR PROTECTOR

RULES FOR SAFE INSTALLATION AND OPERATION

Read these rules and the instructions carefully.

SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

F36 BLOWER KIT

An Optional Blower kit is available for the 2941 Wonderwood automatic wood burning circulator heater. If this kit is not available where you have purchased this Wonderwood heater, you can purchase the F36 Blower Kit directly from the factory. To order contact the United States Stove Company at the address and telephone number given on the back page.

1.Check local codes. The installation must comply with their rulings. Do not install this heater in a mobile home or trailer.

2.Always connect this heater to a chimney or vent to the outside. Never vent to another room or inside a building.

3.Do not connect a WOOD burning heater to an aluminum Type B gas vent. This is not safe and is prohibited by all codes. This

heater requires connection to approved chimneys: Either a factory built 6" UL 103HT or a lined and approved and recently in spected and cleaned masonry chimney with a 6" flue, preferably round. A larger masonry flue may be used, so long as the flue-section diameter is not greater than 50 sq. in.

The chimney portion (whether factory-built

2

19

Page 2
Image 2
United States Stove 2941 owner manual F36 BLOWER KIT, Tools And Material Needed, Circulator Dimensions, Materials