TROUBLE SHOOTING ‐ continued
Door Glass has soot buildup at a fast rate and flame is lazy with black tips.
The vent pipe (including air intake) may be dirty or partially blocked restricting airflow to the unit.
The intake butterfly valve might be set at too low position.(see page 15 )
Burn pot holes are blocked. Let the unit cool and clean burn pot and burn pot liner (be sure to follow instructions for disposal of ashes found on page 29)
Circuit board malfunction. Time the fuel feed light at each setting (after the stove has completed the initial "Start Up" sequence. Check the timing against the timing chart (found below), if the auger motor runs constantly there is a problem with the circuit board
Combustion blower is not operating. Check the exhaust blower is operating, if not bypass the exhaust temperature switch; if the motor operates replace the exhaust temperature switch. If the exhaust blower still does not work apply 120 volts directly to the exhaust blower motor, if the motor does not work replace the exhaust blower motor.
Poor fuel quality. The type of pellets being used may be of poor quality, if possible try a different brand of pellets (refer to fuel type information on page 3).
| Control Board Timing |
|
|
|
|
Heat level 1 | Auger on 2 seconds | Auger off 5 seconds |
Heat level 2 | Auger on 3 seconds | Auger off 3 seconds |
Heat level 3 | Auger on 5 seconds | Auger off 3 seconds |
Heat level 4 | Auger on 7 seconds | Auger off 3 seconds |
|
|
|
Heat level 5 | Auger on 10 seconds | Auger off 3 seconds |
36