GAS CONNECTION

NOTICE

Aqualifiedgasapplianceinstallermustconnectthefireplacetothegassupply. Consultalllocalcodes.

CAUTION

Usenewblackironorsteelpipeonly. Internallytinnedcoppertubingcanbeusedinsomeareas when permitted by local codes. Only use pipe of 1/2" or greater diameter to allow full gas volumetoheater.Excessivepressurelosswilloccurifthepipeistoosmall.

Amanualshutoffvalve,unionandplugged1/8"NPTpressuretappingpointmustbeinstalled upstream of the heater (FIGURE 4).

Asedimenttrapmustbeinstalledupstreamoftheheatertopreventmoistureandcontaminants from passing through the pipe to the heater controls and burners. Failure to do so could prevent the heater from operating reliably (FIGURE 4).

TO HEATER

CONTROL VALVE

PIPE

COUPLING

SEDIMENT TRAP

STAINLESS

FLEXIBLE TUBE

PIPE

MANUAL

SHUTOFF VALVE

TEE JOINT

PIPE NIPPLE

CAP

IMPORTANT: Loosen the pipe adapter on the flex tube before installing to the systempiping.

FIGURE 5. Gas Connection

CHECK GAS TYPE: The gas supply must be the same as stated on heater's rating plate. If the gas supply is different, DO NOT INSTALL the heater. Contact your dealer for the correct model.

WARNING

Connectingdirectlytoanunregulatedpropane/LPGtankcancauseanexplosion.

9

Page 9
Image 9
United States Stove B9945L manual GAS Connection, Gas Connection