OPERATING INSTRUCTIONS
LIGHTING INSTRUCTIONS
1.STOP! Read the safety information on the previous page.
2.Set the thermostat to lowest setting.
3.Turn off all electrical power and open the access door.
4.Push in gas control (B) slightly and turn clock
wise | to "OFF". |
5.Push "ON / OFF" switch to "OFF" position.
B
D
A
C
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on the previous page. If you don't smell gas, go on to the next step.
7.Depressknob(B)andturngascontrolknob
counterclockwise | to "Pilot". |
8.Push in knob (B) all the way and hold in. Immediately light the pilot by pushing in on the piezo button (A). Continue to hold the control knob in for about one(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4 through8.
TOP VIEW OF BURNER ASSEMBLY
If the pilot does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn control knob to "OFF" and call your gas supplier.
9.Turn valve knob clockwise to "ON".
10.Wait about one minute then turn burner switch
(D) to "ON". It will take a few minutes for the thermopile located on top of the pilot to heat up.
NOTE: If unit is equipped with remote
11.Adjust flame height with the
12.Turn on all electrical power to the appliance.
13.Close access door.
NOTE: It is normal for the new heater to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.
It is recommended that you burn your new heater for at least two(2) hours the first time you use it. If optional fan kit is installed, leave it turned off for the break in period.
TURN OFF GAS TO APPLIANCE
1.Open access door.
2.Turn switch (D) to "OFF"
3.Unplug all electric power (optional blower) if service is to be performed.
4. Push in gas control knob slightly and turn clockwise | to the "OFF" position. |
5.Close access door.
13