Troubleshooting Guide

Self-diagnosisFunction

Error Indicator

The self-diagnosis function of the air conditioner is used to identify any troubles that may exist.

Refer to the table below to determine the error code associated with the LED signals given by the indoor air con- ditioner's display.

If more than two problems occur simultaneously, one error code of most severity is displayed.

After an error has occurred, if the error is fixed/cleared, the LED display representing the error code (shown in the table below) will also be cleared simultaneously.

To operate the unit after the occurrence of an error code, it is best to power off the unit and then power on again.

LED1 LED2

Indoor Error

Error code

Description

MPS Variable

LED1

LED2

Indoor Status

 

 

 

 

 

 

00

No Error

 

 

 

ON

 

 

 

 

 

 

01

Indoor Room Thermistor Error

 

1 time

 

OFF

 

 

 

 

 

 

02

Indoor In-Piping Error

 

2 times

 

OFF

 

 

 

 

 

 

05

Communication Error between In and Out

 

5 times

 

OFF

 

 

 

 

 

 

06

Indoor Out-Piping Error

 

6 times

 

OFF

 

 

 

 

 

 

07

Differnt mode operation

 

7 times

 

OFF

 

 

 

 

 

 

10

Indoor fan motor locked error

 

 

1 times

OFF

 

 

 

 

 

 

Outdoor Error

Error code

Description

MPS Variable

LED1(Red)

LED2(Green)

Indoor Status

 

 

 

 

 

 

33

D-Pipe High(Normal)

 

3 times

3 times

OFF

 

 

 

 

 

 

44

Outdoor Air Thermistor Error(Open/Short)

 

4 times

4 times

OFF

 

 

 

 

 

 

45

Cond Pipe Thermistor Error(Open/Short)

 

4 times

5 times

OFF

 

 

 

 

 

 

47

Const. D-Pipe Thermistor Error(Open/Short)

 

4 times

7 times

OFF

 

 

 

 

 

 

51

Capcity Error(High/Low)

 

5 times

1 times

OFF

 

 

 

 

 

 

Wall Mounted Multi-Zone Split System Air Conditioner

- 64 -

Page 64
Image 64
Heat Controller A-MMH24FA-1, B-MMH12FA-1, B-MMC12FA-1 Self-diagnosis Function, Indoor Error, Outdoor Error, Error Indicator