Hoshizaki M029-897 service manual G. Error Codes

Models: M029-897

1 39
Download 39 pages 1.19 Kb
Page 27
Image 27
G. Error Codes

G. Error Codes

When the control board detects an error, the display shows one of the following error codes in the display mode. Error codes other than E1 and E2 are displayed as "EE" at the time of occurrence. To see the actual error code, see the error log.

1.With the unit on, press and hold the "SERVICE 1" button for 3 seconds. Display changes to "n1".

2.Use the "SERVICE 1" and "SERVICE 2" buttons to move through the list until "h4" is displayed.

3.Press the "RESET" button to view the error log. Displays up to 5 errors with the most recent error first.

4.Press the "RESET" button to return to list. To clear error log history, press and hold the "SERVICE 1" and "SERVICE 2" buttons simultaneously for 5 sec.

5.Display returns to normal if no buttons are touched for 20 sec.

Error Codes

Error

Problem

Corrective Action/Reset Details

Code

 

 

 

 

 

E1

Freeze Cycle Backup Timer

Check for inlet water valve leaking by, hot gas valve

 

Freeze cycle backup timer (Control Board Setting

leaking by, pump motor not pumping, thermostatic

 

6) has terminated.

expansion valve not feeding properly, low charge, or

 

45 min. after water tank starts to close in

inefficient compressor.

 

preceding harvest cycle, unit stops if the

 

 

evaporator temperature is above 32°F (0°C).

Press the "RESET" button to reset.

 

 

 

E2

Harvest Cycle Backup Timer

Check for open thermistor, HGV not opening, TXV

 

Harvest cycle backup timer has terminated.

leaking by, low charge, or inefficient compressor.

 

30 min. after water tank starts to open in harvest

 

 

cycle, unit stops if harvest cycle termination

Press the "RESET" button to reset.

 

temperature (Control Board Setting 1) has not

 

 

been reached.

 

 

 

 

EE

Water Tank Opening Backup Timer

Check actuator motor and control board.

(E3)

3-minute opening backup timer starts when water

 

 

tank starts to open.

Press the "RESET" button to reset.

 

If actuator motor's internal position sensor

 

 

does not indicate water tank is fully open within

 

 

3 minutes, display shows "EE" and unit stops for

 

 

60 minutes.

 

 

If error recurs after unit resumes operation,

 

 

display shows "EE" and unit shuts down.

 

 

 

 

EE

Water Tank Closing Backup Timer

Check actuator motor and control board.

(E4)

3-minute closing backup timer starts when water

 

 

tank starts to close.

Press the "RESET" button to reset.

 

If actuator motor's internal position sensor does

 

 

not indicate water tank is fully closed within

 

 

3 minutes, display shows "EE" and unit stops for

 

 

60 minutes.

 

 

If error recurs after unit resumes operation,

 

 

display shows "EE" and unit shuts down.

 

 

 

 