Error Codes
Error | Problem | Corrective Action/Reset Details |
Code |
|
|
EE | High Evaporator Temperature | Check for harvest problem (stuck HGV or control |
(E5) | If evaporator temperature 140°F (60°C) or higher | board relay), hot water entering unit, or shorted |
| for 5 sec., unit stops. | thermistor. |
|
| Press the "RESET" button to reset. |
|
|
|
EE | Condenser Thermistor Error | Replace condenser thermistor. |
(E9) | If condenser thermistor is open or shorted for |
|
| 2 sec., unit stops. |
|
| Note: |
|
| thermistor, therefore E9 error will not occur. |
|
|
|
|
EE | Control Board Error | Replace control board. |
(EA) | If model data IC is defective, unit stops. |
|
|
|
|
EE | Evaporator (Cube Control) Thermistor Error | Replace evaporator thermistor. |
(EC) | If evaporator thermistor is open or shorted for |
|
| 2 sec., unit stops. |
|
|
|
|
EE | Water Regulating Valve Error | Check water regulating valve. |
(Ed) | If water regulating valve thermistor detects a |
|
| temperature below the water regulating valve | Press the "RESET" button to reset. |
| error detection temperature (Control Board |
|
| Setting 36), error is displayed but unit continues |
|
| to operate. |
|
| Note: |
|
| regulating valve, therefore Ed error will not occur. |
|
|
|
|
H. Quick Adjustments
1. Dimple Diameter
The factory set dimple diameter is 3/16" (5 mm). NOTICE! Do not decrease the dimple diameter below 3/16" (5 mm).
a)To increase dimple diameter:
1)Remove front panel.
2)Press the "SERVICE 1" button to view the current freeze cycle termination temperature setting.
3)Press the "SERVICE 1" button to raise freeze cycle termination temperature setting (Control Board Setting 2). Temperature setting rises in .5°C increments. The "." in the lower, right corner of the display indicates .5°C. Default is
4)Once the display returns to "on" (20 seconds), the new setting is saved.
b)To decrease dimple diameter:
1)Remove front panel.
2)Press the "SERVICE 2" button to view the current freeze cycle termination temperature setting.