Hoshizaki M029-897 E. Control Board Information Display, Press the RESET button to return to list

Models: M029-897

1 39
Download 39 pages 1.19 Kb
Page 23
Image 23
E. Control Board Information Display

Control Board (CB) Setting Menu

 

 

 

 

IM-500SAA

Category

No.

Item

Range

Default

Water Tank

74

Water Tank Ice Control Lower Temperature

0 to 40°C

27

Ice Control

 

See CB Setting 70, 71, 72, 74 description above.

(1°C increments)

 

& Harvest

 

Harvest Cycle Low Temperature Control

 

 

Cycle Low

 

If control board thermistor temperature at the

 

 

Temperature

 

beginning of harvest cycle is equal to or less than

 

 

Control

 

the harvest cycle low temperature control setting, hot

 

 

 

 

gas valve repeatedly energizes for 40 seconds then

 

 

 

 

de-energizes for 40 seconds to promote a balanced

 

 

 

 

harvest across the evaporator plate.

 

 

E. Control Board Information Display

1.With unit on, press and hold the "SERVICE 1" button for 3 seconds. Display changes to "n1".

2.Use the "SERVICE 1" and "SERVICE 2" buttons to move through the list.

3.Press the "RESET" button to view the item’s value.

4.Press the "RESET" button to return to list.

5.Display returns to normal if no buttons are touched for 20 seconds.

Control Board Information Display

 

 

 

History Cleared by

 

 

 

Pressing and Holding

 

 

 

SERVICE 1 and

 

 

 

SERVICE 2 Buttons

 

 

 

Simultaneously for

 

 

 

5 Sec. when Item Value

No.

Item

Description

is Displayed?

 

 

 

 

n1

Freeze Cycle Time

0 to 99 min.

No

 

During Freeze Cycle: Time since freeze cycle

 

 

 

started.

 

 

 

After Freeze Cycle: Time of previous freeze cycle.

 

 

 

 

 

 

n2

Freeze Cycle Completion Rate

0 to 100%

No

 

During Freeze Cycle: Percent of freeze cycle

00 = 100%

 

 

completed.

 

 

 

After Freeze Cycle: Percent of previous freeze

 

 

 

cycle completed.

 

 

 

 

 

 

n3

Current Evaporator (Cube Control) Thermistor

°C

No

 

Temperature

 

 

 

 

 

 

n4

Current Control Board Thermistor Temperature

°C

No

 

 

 

 

n5

Water Temperature

"H" if Higher than 48°F

No

 

Temperature at evaporator (cube control)

(9°C)

 

 

thermistor 30 seconds after pump motor

"L" if 48°F (9°C) or

 

 

energized in freeze cycle plus the water

Lower

 

 

temperature correction value (Control Board

 

 

 

Setting 13).

 

 

n6

Current Condenser Thermistor Temperature

°C

No

 

Not Applicable to IM-500SAA

 

 

23

Page 23
Image 23
Hoshizaki M029-897 E. Control Board Information Display, Use the SERVICE 1 and SERVICE 2 buttons to move through the list