B. Performance Data

Pressure data is recorded at 5 min. into freezing cycle. The data not in bold should be used for reference only.

1. IM-500SAA

APPROXIMATE ICE

AMBIENT TEMP.

 

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

 

 

 

 

 

 

 

 

 

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

70/21

 

500

227

 

481

218

 

447

203

 

 

 

 

80/27

 

485

220

 

456

207

 

417

189

lbs./day

 

kg./day

 

90/32

 

481

218

 

435

197

 

397

180

 

 

100/38

 

471

214

 

426

193

 

363

165

 

 

APPROXIMATE ELECTRIC

70/21

 

 

920

 

 

941

 

 

967

CONSUMPTION

80/27

 

 

936

 

 

968

 

 

993

 

 

 

 

90/32

 

 

941

 

 

990

 

 

1016

watts

 

 

 

100/38

 

 

945

 

 

996

 

 

1040

APPROXIMATE WATER

70/21

 

105

0.40

 

99

0.38

 

92

0.35

CONSUMPTION PER 24 HR.

80/27

 

101

0.38

 

92

0.35

 

84

0.32

 

 

 

 

90/32

 

99

0.38

 

86

0.33

 

78

0.30

gal./day

 

m3/day

100/38

 

91

0.34

 

84

0.32

 

71

0.27

FREEZING CYCLE TIME

70/21

 

 

17

 

 

18

 

 

20

 

 

 

 

80/27

 

 

18

 

 

20

 

 

23

 

 

 

 

90/32

 

 

18

 

 

22

 

 

24

min.

 

 

 

100/38

 

 

19

 

 

23

 

 

27

HARVEST CYCLE TIME

70/21

 

 

3.6

 

 

3.0

 

 

2.0

 

 

 

 

80/27

 

 

3.2

 

 

2.2

 

 

2.0

 

 

 

 

90/32

 

 

3.0

 

 

1.6

 

 

1.5

min.

 

 

 

100/38

 

 

2.4

 

 

1.6

 

 

1.4

HEAD PRESSURE

70/21

 

210

14.8

 

231

16.3

 

255

18.0

 

 

 

 

80/27

 

226

15.9

 

260

18.2

 

281

19.7

 

 

 

 

90/32

 

231

16.3

 

283

19.9

 

306

21.5

PSIG

kg/cm2G

100/38

 

234

16.5

 

288

20.3

 

327

23.0

SUCTION PRESSURE

70/21

 

42

3.0

 

45

3.1

 

48

3.4

 

 

 

 

80/27

 

44

3.1

 

48

3.4

 

52

3.6

 

 

 

 

90/32

 

45

3.1

 

51

3.6

 

55

3.8

PSIG

kg/cm2G

100/38

 

45

3.2

 

52

3.6

 

58

4.1

TOTAL HEAT OF REJECTION FROM CONDENSER

 

4,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

1,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]