United States Stove C226 PART E - Figure, Does Not Passthrough A Combustiblewall, Part C Figure

Models: C226

1 12
Download 12 pages 10.87 Kb
Page 8
Image 8
PART B FIGURE 8 -

PART B FIGURE 8 -

(FIGURE 8 CONTINUED)

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

 

 

FLUE

FACTORY-BUILT

 

CHIMNEY

 

 

CHIMNEY LENGTH

 

 

 

NONSOLUBLE

 

 

REFACTORY

 

 

CEMENT

 

 

CHIMNEY LENGTH

 

 

FLUSH WITH INSIDE

 

AIR SPACE

OF FLUE

 

9 IN. MINIMUM

 

 

MASONRY CHIMNEY CONSTRUCTED

TO NFPA 211

AIR SPACE

MINIMUM CLEARANCE 9 IN. ALL AROUND

CHIMNEY CONNECTOR PART C FIGURE 8 TO HEATER

USE CHIMNEY MFRS. PARTS TO

ATTACH CONNECTOR SECURELY

SOLID INSULATED, LISTED FACTORY-BUILT CHIMNEY LENGTH

SHEET STEEL SUPPORTS

(24 GAUGE MIN. THICKNESS)

PART C FIGURE 8

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

TWO VENTILATED AIR CHANNELS EACH 1 INCH. CONSTRUCTED OF SHEET STEEL.

CHIMNEY THIMBLE

CHIMNEY FLUE

MASONRY CHIMNEY CONSTRUCTED TO NFPA 211

24 GAUGE

VENTILATED THIMBLE WITH TWO 1 INCH AIR CHANNELS

CHIMNEY CONNECTOR

TO HEATER

MINIMUM 6 IN. GLASS

FIBER INSULATION ALL AROUND

SHEET STEEL SUPPORTS (24 GAUGE MIN. THICKNESS)

PART D FIGURE 8

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO

SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

SHEET STEEL SUPPORTS

 

 

MINIMUM CLEARANCE

 

 

2 IN. ALL AROUND

CHIMNEY SECTION

 

 

 

CHIMNEY THIMBLE

1 IN. AIR SPACE TO

 

CHIMNEY LENGTH

 

 

CHIMNEY

 

CHIMNEY CONNECTOR

 

TO HEATER

CONNECTOR

FLUE

 

 

 

 

CHIMNEY

SOLID INSULATED, LISTED

AIR SPACE

FACTORY-BUILT CHIMNEY

2 IN.

LENGTH (12 IN. LONG MIN.)

 

SHEET STEEL SUPPORTS

MASONRY CHIMNEY CONSTRUCTED

(24 GAUGE MIN. THICKNESS)

 

TO NFPA 211

 

PART E - (Figure 8)

In addition to the methods shown by A, B, C, and D of Figure 8, a listed factory-built wall pass-through system may be purchased and installed according to the instructions packaged with it to provide a safe method of passing chimney connector through a combustible wall for a connection to a masonry chimney.

CONNECTION OF CHIMNEY CONNECTORTO A MASONRY CHIMNEYWHEN CHIMNEY CONNECTOR

DOES NOT PASSTHROUGH A COMBUSTIBLEWALL

If the chimney connector does not have to pass through a combustible wall to get to a masonry chimney, simply connect the chimney connector directly to the masonry chimney's chimney thimble as described and shown by parts C and D of Figure 8. Remember, the chimney connector should extend into the chimney thimble to the innerface of the chimney flue but not beyond; if the chimney connector is extended through the chimney thimble into the chimney flue, resistance to the flow of smoke and gases up the chimney will occur; that flow resistance will have an adverse affect on the operation and performance of the heater and venting system.

8

Page 8
Image 8
United States Stove C226 PART E - Figure, Does Not Passthrough A Combustiblewall, Part B Figure Continued, Part C Figure