PART A, FIGURE 8

(FIGURE 5 CONTIUED ON NEXT PAGE)

MINIMUM 12 IN.

TO COMBUSTIBLES

CHIMNEY FLUE

MASONRY CHIMNEY CONSTRUCTED TO NFPA 211

MINIMUM CHIMNEY CLEARANCE TO BRICK AND COMBUSTIBLES IS 2 IN.

MINIMUM CLEARANCES 12 IN. OF BRICK ALL AROUND

CHINEY CONNECTOR TO HEATER

FIRE CLAY LINER

(5/8" MIN. WALL THICKNESS)

MIN. 3-1/2" THICK BRICK

MASONRY WALL

1.Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall. A fireclay liner (ASTM C315 or equivalent) having a 5/8" minimum wall thickness must be used and it must be at least 12" away from any material that could catch fire. The inside diameter of the fireclay liner shall be sized for the proper snug fit of a 6" diameter chimney connector pipe. The fireclay liner shall run from the outer surface of the brick wall to, but not beyond, the inner surface of the chimney flue and shall be firmly cemented in place. See Part A of Figure 8.

2.Use a solid insulated listed factory-built chimney length having an inside diameter of 6" and having 1" or more of solid insulation. There must be at least a 9" air space between the outer wall of the chimney length and any combustible materials. The inner end of the chimney length shall be flush with the inside of the masonry chimney flue shall be sealed to the flue and to the brick masonry penetration with nonwater-soluble refractory cement. Sheet steel supports which are at least 24 gauge(0.024") in thickness shall be securely fastened to wall

surfaces on all sides. Fasteners between supports and the chimney length shall not penetrate the chimney liner. See Part B of Figure 8.

3.Use a 10" diameter ventilated thimble made of at least 24 gauge(0.024") steel having two 1" air channels. The venti- lated thimble must be separated from combustible materials by a minimum of 6" glass fiber insulation. The opening in the combustible wall shall be covered and the thimble supported with sheet steel supports which are at least 24 gauge (0.024") in thickness. The sheet steel supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold the chimney section. Fasteners used to secure chimney sections shall not penetrate chimney flue liner. See Part C of Figure 8.

4.Use an 8" inside diameter solid insulated listed factory-built chimney length which has 1" or more of solid insulation. The minimum length of this chimney section shall be 12" and will serve as a pass-through for the 6" diameter chimney connector. There must be at least a 12" air space between the outer wall of the chimney section and any combustible materials. The chimney section shall be concentric with and spaced 1" away from the chimney connec tor by means of sheet steel support plates on both ends of the chimney section. The opening in the combustible wall shall be covered and the chimney section supported on both sides with sheet steel supports which are at least 24 gauge (0.024") in thickness. The sheet steel supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold the chimney section. Fasteners used to secure chimney sections shall not penetrate chimney flue liner. See Part C of Figure 8.

5.A listed factory-built wall pass-through system may be purchased and installed according to the instructions pack aged with it to provide a safe method of passing the chimney connector through a combustible wall for connection to a masonry chimney.

Additional requirements pertaining to Figure 8 and the above wall pass-through systems:

1.Insulation material used as part of wall pass-through system shall be of noncombustible material and shall have a thermal conductivity of 1.0 Btu • in./ft.² • °F (4.88 kg • cal/hr • m² • °C) or less

2.All clearances and thicknesses are minimums: larger clearances and thickness are acceptable.

3.A chimney thimble, as shown for 3" and 4" above (Parts C and D respectively of Figure 8) shall be for types "3" and 4" connections to facilitate removal of the chimney connector for cleaning. The chimney thimble shall be of ASTM C315 fireclay with 5/8" minimum wall thickness , or material or equivalent durability. The inside diameter of the thimble shall be sized for the proper snug fit of a 6" diameter chimney connector pipe. The thimble shall be installed without damage to the chimney flue. The thimble shall extend through the chimney wall to, but not beyond, the inner surface of the chimney flue and shall be permanently cemented in place with high temperature cement.

4.A chimney connector to a masonry chimney, except for 2" above (Part B of Figure 8), shall extend through the wall pass-through system to the inner face of the chimney flue, but not beyond. It does not have to be fastened in place so long as it cannot accidently be pulled out of the chimney or shoved into the chimney flue. If fasteners are used to secure the chimney connector to a masonry chimney, the fasteners shall not penetrate the chimney flue liner.

5.Any material used to close up any opening for the connector shall be noncombustible.

7

Page 7
Image 7
United States Stove C242 owner manual Contiued on Next

C242 specifications

The United States Stove C242 is an innovative and efficient wood-burning stove designed to provide warmth and comfort for homes while emphasizing energy efficiency and environmental responsibility. This model is an exemplary representation of the quality and performance that United States Stove Company is known for, making it a popular choice among homeowners seeking an effective heating solution.

One of the main features of the C242 is its robust construction. Built from high-quality materials, the stove offers durability and longevity, ensuring it remains a reliable source of heat for years. The solid cast iron top and heavy-duty steel body contribute to its sturdy build, allowing the stove to withstand high temperatures and frequent use.

The C242 is designed to deliver exceptional heat output with a heating capacity sufficient for medium to large rooms. Its innovative firebox design allows for an extended burn time, providing homeowners with prolonged warmth without the need for constant refueling. This feature not only enhances user convenience but also maximizes fuel efficiency.

In terms of technology, the C242 incorporates advanced airflow control systems. This ensures optimal combustion, reducing smoke emissions and enhancing overall efficiency. The air intake system is easily adjustable, allowing users to quickly modify the burn rate and heat output to match their specific heating needs. This feature is crucial for maintaining a clean burn, which is beneficial for both the environment and indoor air quality.

Another notable characteristic of the C242 is its aesthetic appeal. With a classic design, it complements various home decors, adding a touch of rustic charm. The stove typically comes with an optional blower, enhancing heat distribution throughout the room and improving overall comfort.

Safety is also a paramount consideration in the design of the C242. Equipped with a secure door and an efficient ash pan design, the stove allows for easy cleaning and maintenance while minimizing the risk of accidents.

Overall, the United States Stove C242 is a perfect blend of efficiency, style, and advanced technology, making it an excellent choice for homeowners looking for a reliable wood-burning stove. With its robust construction, superior heating capacity, and user-friendly features, it stands out as a practical and appealing option for efficient heating solutions.