United States Stove EC95 warranty PART E - Figure

Models: EC95

1 20
Download 20 pages 57.09 Kb
Page 7
Image 7
PART E - (Figure 5)

PART C

FIGURE 5

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO

SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

TWO VENTILATED AIR CHANNELS EACH 1 INCH. CONSTRUCTED OF SHEET STEEL.

CHIMNEY THIMBLE

CHIMNEY FLUE

MASONRY CHIMNEY CONSTRUCTED TO NFPA 211

24 GAUGE

VENTILATED THIMBLE WITH TWO 1 INCH AIR CHANNELS

CHIMNEY CONNECTOR

TO HEATER

MINIMUM 6 IN. GLASS

FIBER INSULATION ALL AROUND

SHEET STEEL SUPPORTS (24 GAUGE MIN. THICKNESS)

PART D FIGURE 5

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

SHEET STEEL SUPPORTS

CHIMNEY SECTION

CHIMNEY THIMBLE

 

CHIMNEY

FLUE

CONNECTOR

 

2 IN.

CHIMNEY

AIR SPACE

 

MASONRY CHIMNEY CONSTRUCTED

TO NFPA 211

MINIMUM CLEARANCE 2 IN. ALL AROUND

1 IN. AIR SPACE TO CHIMNEY LENGTH

SHEET STEEL SUPPORTS (24 GAUGE MIN. THICKNESS)

PART E - (Figure 5)

In addition to the methods shown by A, B, C, and D of Figure 5, a listed factory-built wall pass-through system may be purchased and installed according to the instructions packaged with it to provide a safe method of passing chimney connector through a combustible wall for a connection to a masonry chimney.

EC95

7

Page 7
Image 7
United States Stove EC95 warranty PART E - Figure