There are basically two methods of metal prefabricated chimney installation. One method is to install the chimney inside the residence through the ceiling and the roof. The other method is to install an exterior chimney that runs up the outside of the residence.

REMEMBER: Follow the chimney manufacturer's installation instructions and maintain the manufacturer's specified clear- ance distance.

Additional chimney information is presented throughout this manual. READ IT THOROUGHLY TO BE MORE THOR-

OUGHLY INFORMED.

CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY THROUGH A COMBUSTIBLE WALL

PART A, FIGURE 7

(FIGURE 7 CONTINUED ON NEXT PAGE)

MINIMUM 12 IN.

TO COMBUSTIBLES Manual background

CHIMNEY FLUE

MASONRY CHIMNEY CONSTRUCTED TO NFPA 211

MINIMUM CHIMNEY CLEARANCE TO BRICK AND COMBUSTIBLES IS 2 IN.

MINIMUM CLEARANCES 12

IN. OF BRICK ALL AROUND

CHIMNEY CONNECTOR TO HEATER

FIRE CLAY LINER

(5/8" MIN. WALL THICKNESS)

MIN. 3-1/2" THICK BRICK

MASONRY WALL

PART B FIGURE 5 -

(FIGURE 5 CONTINUED)

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO

SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

FACTORY-BUILT

NONSOLUBLE

CHIMNEYFLUE

AIRSPACE

CHIMNEY LENGTH

 

MINIMUM CLEARANCE

 

9 IN. ALL AROUND

 

 

 

 

REFACTORY

 

CHIMNEY CONNECTOR

 

 

TO HEATER

 

CEMENT

 

 

 

 

 

CHIMNEY LENGTH

 

 

 

FLUSH WITH INSIDE

 

USE CHIMNEY MFRS. PARTS TO

AIR SPACE

OF FLUE

 

 

ATTACH CONNECTOR SECURELY

9 IN. MINIMUM

 

 

 

 

 

 

 

 

SOLID INSULATED, LISTED

 

 

 

FACTORY-BUILT CHIMNEY LENGTH

 

MASONRY CHIMNEY CONSTRUCTED

SHEET STEEL SUPPORTS

 

TO NFPA 211

 

(24 GAUGE MIN. THICKNESS)

6

EC95