![RATINGS AND DATA](/images/new-backgrounds/54311/5431153x1.webp)
|
|
| RATINGS AND DATA |
|
|
| ||||
| NATURAL GAS AND PROPANE GAS |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| § | § | § ** | † |
|
| ∆ | Natural | Propane |
|
Boiler | A.G.A. | Heating | I=B=R | NetRating | No. | Recommended | Gas | Orifice | Water | |
No. | Input | Capacity | NetOutput | Sq. Ft. HW | of | Air Cushion | Orifice | Drill | Content | |
| Btu/Hr. | Btu/Hr. | Btu/Hr | @ 170 | o | Burners | Tank | Drill Size | Size | (Gals.) |
|
| |||||||||
MGB 50 | 50,000 | 42,000 | 37,000 | 243 |
| 1 | 15 | 30 | 47 | 2.4 |
MGB 75 | 75,000 | 63,000 | 55,000 | 365 |
| 2 | 15 | 33 | 50 | 4.0 |
MGB 100 | 100,000 | 83,000 | 72,000 | 481 |
| 2 | 30 | 30 | 47 | 4.0 |
MGB 125 | 125,000 | 104,000 | 90,000 | 603 |
| 3 | 30 | 31 | 49 | 5.6 |
MGB 150 | 150,000 | 124,000 | 108,000 | 719 |
| 3 | 30 | 30 | 47 | 5.6 |
MGB 175 | 175,000 | 143,000 | 124,000 | 829 |
| 4 | 30 | 31 | 49 | 7.2 |
MGB 200 | 200,000 | 165,000 | 143,000 | 957 |
| 4 | 30 | 30 | 47 | 7.2 |
MGB 250 | 250,000 | 205,000 | 178,000 | 1189 |
| 5 | 30 | 30 | 47 | 8.8 |
|
|
|
|
|
|
|
|
|
|
|
MGB 300 | 299,999 | 243,000 | 214,000 | 1368 |
| 6 | 60 | 30 | 47 | 10.4 |
STANDARD EQUIPMENT: Boiler Jacket, Cast Iron Boiler Battery, Combination Aquastat Relay, Theraltimeter Gauge,Circulator with return piping to boiler, Main Gas Burners, Combination 24 Volt Gas Control (includes automatic gas valve, gas pressure regulator, automatic pilot, safety shutoff, pilot flow adjustment, pilotfilter), A.S.M.E. Relief Valve, Drain Cock, Spill Switch, Rollout Switch, Automatic Vent damper. Not shown are a wiring harness, thermocouple, and
OPTIONAL EQUIPMENT: Intermittent Electric Ignition Pilot System.
EXPLANATORY NOTES
§For elevations above 2000 feet, ratings should be reduced at a rate of 4% for each 1000 feet above sea level.
∆Tank sized for
†Base on 170' temperature in radiators.
**For equivalent square feet of radiation, divide I=B=R output by 150.
PAGE 26