ELECTRICAL WIRING

SEE ADDENDUM " A" FOR WIRING DIAGRAMS

AND COMPONENT CODING.

Electrical wiring must conform with the National Electrical Code, ANSI/NFPA No. 70-1990 when installed in the United states, the CSA C22.1 Canadian Electrical Code, Part 1, when installed in Canada, and/or the local authority having jurisdiction.

WARNING: 1.When an external electrical source is utilized, the boiler, when installed MUST BE electrically grounded in accordance with these requirements.

2. Install a fused disconnect switch between boiler and meter at a convenient location.

THERMOSTAT INSTALLATION

1.Thermostat should be installed on an inside wall about four feet above the floor.

2.NEVER install a thermostat on an outside wall.

3.Do not install a thermostat where it will be affected by:

A.Drafts

B.Hot or Cold Pipes

C.Sun Light

D.Lighting Fixture

E.Television

F.A Fireplace or Chimney

4.Check thermostat operation by raising and lowering thermostat setting as required to start and stop the burners.

5.Instructions for the final adjustment of the thermostat are packaged with the thermostat (adjusting heating anticipator, calibration, etc.)

LIGHTING INSTRUCTIONS

WARNING:

IFYOUDONOTFOLLOWTHESEINSTRUCTIONSEXACTLY,

A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

Before any procedures are attempted on this appliance, it is necessary to determine if the ignition system is electric or standing pilot. If you are un-certain, contact the manufacturer before proceeding.

CAUTION: Before lighting any type of pilot burner (standing or intermittent), make certain the hot water boiler and system are full of water to minimum pressure of 12 lbs. per square inch in the system, and also make certain that the system is vented of air. Set the operating control of thermostat to a “below” normal setting. Refer to the following appropriate lighting instruction.

PAGE 13

Page 14
Image 14
Utica Gas-fired Boiler manual Electrical Wiring, Thermostat Installation, Lighting Instructions

Gas-fired Boiler specifications

The Utica Gas-fired Boiler is a highly efficient heating solution designed for residential and commercial applications. Recognized for its reliability and durability, the Utica Gas-fired Boiler utilizes gas as a clean energy source, which not only reduces emissions but also lowers operational costs. With various models available, this boiler caters to a wide range of heating needs, making it a versatile choice for different environments.

One of the main features of the Utica Gas-fired Boiler is its impressive energy efficiency. Many models are equipped with advanced combustion technology that ensures optimal fuel utilization, resulting in lower gas consumption and environmental impact. This efficiency is often reflected in high AFUE (Annual Fuel Utilization Efficiency) ratings, confirming the boiler's ability to convert a significant portion of fuel into usable heat.

The Utica Gas-fired Boiler employs a diversified product line, which includes both steam and hot water boiler systems. This flexibility allows users to choose the system that best suits their heating requirements. Additionally, the boilers are designed with user-friendly controls that facilitate easy operation and maintenance.

In terms of technology, Utica integrates multiple innovative features into their gas-fired boilers. The use of a modulating gas valve enables the boiler to adjust its output to match the heating demand, promoting energy efficiency and comfort. Many models also utilize a sealed combustion design that pulls in outside air for combustion, enhancing safety and improving performance in tightly sealed homes.

Moreover, the construction of Utica Gas-fired Boilers emphasizes durability. They are built from high-quality materials like cast iron or stainless steel, ensuring a long lifespan and resistance to corrosion. The robust design also facilitates easy servicing, with accessible components that minimize downtime in the event of maintenance or repairs.

Safety is another critical aspect of the Utica Gas-fired Boiler design. Features such as built-in safety controls, pressure relief valves, and flame rollout switches contribute to a safer operating environment.

In conclusion, the Utica Gas-fired Boiler exemplifies an exceptional heating solution characterized by efficiency, flexibility, and durability. With advanced technologies and a strong commitment to safety, it remains a preferred choice for those seeking reliable heating options for their spaces. The combination of low emissions, high performance, and user-friendly operation makes it ideal for modern heating applications.