INSTALLING |
|
|
| 12" |
| Mantel Shelf |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| Underside of | ||||
|
|
|
| 10" |
|
|
|
|
|
|
|
| |||
Continued |
|
|
|
|
|
|
|
|
|
|
| Mantel Shelf | |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 8" |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| 6" |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| 2 1/2" |
|
|
|
|
|
|
|
| All minimum | ||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| distances are | |
| Minimum Non- |
|
|
|
|
|
|
|
|
|
| in inches | |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Combustible |
|
|
|
|
|
|
|
|
|
|
| Log Sets | ||
| Material |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| 8" |
|
| 12" | 15" | 18" | 20" |
| 18", 24", and | ||||
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
| Min. |
|
|
|
|
|
|
|
| 30" Models |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Top of Fireplace | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Hood |
|
|
|
|
|
|
| Opening | ||
|
|
|
|
|
|
| Distances to |
|
|
|
|
| |||
|
|
|
|
| (GA6050, GA6052) |
|
|
|
|
| |||||
|
|
|
|
| Underside of |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Mantel |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 7 - Minimum Mantel Clearances When Using Hood
If your installation does not meet the above minimum clearances, you must:
•operate the logs only with the flue damper open, OR
•raise the mantel to an acceptable height, OR
•remove the mantel.
Floor Clearances
A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).
14"
Combustible Material
Min.
Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level
B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).
Hearth
| Combustible |
|
| Material |
|
5" |
|
|
Min. | Continued | |
| ||
Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring | 13 | |
|
|