Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER installation manual Installing Logs

Models: UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER

1 26
Download 26 pages 29.03 Kb
Page 14
Image 14

VANGUARD FLAME MAX®

UNVENTED NATURAL GAS LOG HEATER

INSTALLATION

Continued

INSTALLING LOGS

WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place one-piece log set on grate to fit as illustrated in Figure 16. Make sure middle section at bottom of log set is seated into "U"-shaped cutout in cen- ter of chassis (see Figure 16). Log will fit securely on chassis. Note: 36" model has more features but fits on the chas- sis the same. IMPORTANT: Make sure log does not cover any burner ports.

2.Place lava rock around base of heater.

One Piece Log Set

Middle

Section at

Bottom of

Log Set

Burner

Chassis

"U"-shaped Cutout in Chassis

Figure 16 - Installing Golden Oak One-Piece Log Set

One Piece

BurnerLog Set ports

Figure 17 - Installing Golden Oak One-Piece Log Set (Top View)

14

105273

Page 14
Image 14
Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER Installing Logs, Place lava rock around base of heater