INFRARED NATURAL GAS HEATER

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information

 

on page 11, column 3.

2. Make sure equipment shutoff valve

 

is fully open.

3.

Turn control knob clockwise

 

to the OFF position.

4.

Wait five (5) minutes to clear out any

 

gas. Then smell for gas, including

 

near the floor. If you smell gas,

 

STOP! Follow “B” in the safety in-

 

formation page 11, column 3. If you

 

don’t smell gas, go to the next step.

5. Turn control knob counterclockwise

 

to the PILOT position. Press

 

in control knob for five (5) seconds

 

(see Figure 15).

 

Note: You may be running this

 

heater for the first time after hook-

 

ing up to gas supply. If so, the con-

 

trol knob may need to be pressed in

 

for 30 seconds. This will allow air to

 

bleed from the gas system.

 

• If control knob does not pop up

 

when released, contact a quali-

 

fied service person or gas sup-

 

plier for repairs.

6. With control knob pressed in, push

 

down and release ignitor button.

 

This will light pilot. The pilot is at-

 

tached to the front of burner. If

 

needed, keep pressing ignitor but-

 

ton until pilot lights.

8.Turn control knob counterclockwise

to desired heating level. The main burner should light. Set control knob to any heat level between HI and LOW (see Figure 17).

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Ignitor Button

 

Control Knob

 

PILOT

LO

 

OFF

 

 

HI

 

IGNITOR

 

 

Figure 15 - Control Knob In The OFF Position

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 16 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set tempera- ture. The control knob can be set to any 2 comfort level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.) Frequent use of your heater will let you determine your own comfort levels.

Note: If pilot does not stay lit, refer to

Troubleshooting, pages 14 through 16.

Also contact a qualified service person

or gas supplier for repairs. Until re-

pairs are made, light pilot with match.

To light pilot with match, see Manual

Lighting Procedure on page 13.

7. Keep control knob pressed in for 30

seconds after lighting pilot. After 30

seconds, release control knob.

Note: If pilot goes out, repeat steps

3 through 7. This heater has a safety

interlock system. Wait one (1) minute

Control Knob

PILOT

 

OFF

 

HI

LO

PILOT

LO

OFF

 

HI

 

VN1800TB

VN3000TB

before lighting pilot again.

Figure 17 - Burner Patterns

12

104820

Page 12
Image 12