Vanguard Heating VP2000BTD Specifications, Replacement Parts, Accessories, Technical Service

Models: VP2800BTD VP2000BTD

1 20
Download 20 pages 17.12 Kb
Page 17
Image 17
SPECIFICATIONS

OWNER’S MANUAL

SPECIFICATIONS

 

VP2000BTD

VP2800BTD

Btu (Variable)

10,000/20,000

15,000/30,000

Type Gas

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (in. of water)

 

 

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

 

 

Heater (Includes knobs & grill)

23.5 x 18.5 x 8.0

23.5 x 25.9 x 8.0

Carton

26 x 20.5 x 9.63

26 x 27.75 x 9.63

Weight (pounds)

 

 

Heater

22

30

Shipping

27

35

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Department at 1-800-323-5190.

When calling DESA International, have ready

your name

your address

• model and serial numbers of your heater

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual.

FLOOR MOUNTING STAND

Model VP2000BTD - GA4000B Model VP2800BTD - GA4010B

For locating heater on the floor, away from a wall. Complete installation

instructions included.

EQUIPMENT SHUTOFF VALVE - GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap.

FAN KITS - GA3100(A,B) AND GA3200T(A,B)

For all models. Provides better heat distribu- tion. Makes heater more efficient. Complete installationandoperatinginstructionsincluded.

Manually-controlled - GA3100(A,B). In- cludes ON/OFF switch.

Thermostatically-controlled-GA3200T(A,B). Includes three settings: ON/OFF/AUTO.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190.

You can also visit DESA International’s technical service web site at

www.desatech.com.

SERVICE PUBLICATIONS

You can purchase service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

• how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your heater

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

When Gas Quality Is Bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

104401

17

Page 17
Image 17