Vanguard Heating VP2000BTD Remedy, Maintenance, page, Owner’S Manual, Troubleshooting, Continued

Models: VP2800BTD VP2000BTD

1 20
Download 20 pages 17.12 Kb
Page 15
Image 15
REMEDY

OWNER’S MANUAL

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1.

Burner orifice is clogged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 13) or replace burner orifice

 

2.

Burner orifice diameter is too small

2.

Replace burner orifice

 

3.

Inlet gas pressure is too low

3.

Contact local propane/LP gas company

 

 

 

 

 

Delayed ignition of burner

1.

Manifold pressure is too low

1.

Contact local propane/LP gas company

 

2.

Burner orifice is clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 13) or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 13) or replace burner orifice

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Yellow flame during burner combustion

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

Maintenance, page 13)

 

2.

Gas regulator defective

2.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Residues from manufacturing processes

1.

Problem will stop after a few hours of

 

 

 

 

operation

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

pane/LP gas company

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

ances (see Figure 4, page 7)

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 13) or replace burner orifice

www.desatech.com