UNVENTED NATURAL GAS FIREPLACE

TROUBLESHOOTING

Continued

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

Burner does not light after ODS/pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 21) or replace burner orifice

 

 

2.

Inlet gas pressure is too low

2.

Contact local natural gas company

 

 

3.

Burner orifice diameter is too small

3.

Replace burner orifice

 

 

4.

Thermopile leads disconnected or im-

4.

Reconnect leads (see Wiring Diagram,

 

 

 

properly connected

 

page 20)

 

 

5.

Burners will not come on in remote

5.

Replace battery in transmitter and

 

 

 

position

 

receiver

 

 

 

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local natural gas company

 

 

2.

Burner orifice clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 21) or replace burner orifice

 

 

 

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 21) or replace burner orifice

 

 

2.

Damaged burner

2.

Replace damaged burner

 

 

3.

Gas regulator defective

3.

Replace gas control

 

 

 

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

 

Maintenance, page 21)

 

 

2.

Gas regulator defective

2.

Replace gas control

 

 

3.

Residues from manufacturing processes

3.

Problem will stop after a few hours of

 

 

 

and logs curing

 

operation

 

 

 

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

 

lation requirements (page 4)

 

 

 

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

 

burner is lit

 

when burner is cold

 

let warm up for a minute

 

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

 

line. Have gas line checked by local

 

 

 

 

 

natural gas company

 

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

 

ances (see pages 8 through 10)

 

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 21) or replace burner orifice

 

 

 

 

 

 

 

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue

1.Turn heater off when using furniture pol- ish, wax, cleaners, or similar products

Remote does not function (GHRC and GHRCT only)

1.Battery is not installed. Battery power is low

1.Replace 9-volt batteries in receiver and remote control

www.desatech.com

18

105269

Page 18
Image 18
Vanguard Heating VYGF33NRA installation manual Observed Problem Possible Cause Remedy

VYGF33NRA specifications

The Vanguard Heating VYGF33NRA is a highly efficient heating solution designed to provide reliable warmth for residential and commercial spaces. This natural gas-fired unit is known for its robust construction and advanced technology, ensuring it meets the needs of various applications while delivering optimal performance.

One of the standout features of the VYGF33NRA is its impressive heating capacity. With an output of 33,000 BTUs, this heater can effectively warm large areas, making it suitable for homes, workshops, and offices. It is particularly advantageous for spaces that demand consistent and reliable heating throughout colder months.

Efficiency is a hallmark of the Vanguard VYGF33NRA. It boasts a remarkable AFUE (Annual Fuel Utilization Efficiency) rating, which signifies its ability to convert a high percentage of gas into usable heat. This feature not only supports energy conservation but also helps reduce overall heating costs, making it an eco-friendly choice for consumers.

The VYGF33NRA is equipped with a state-of-the-art electronic ignition system, ensuring quick and reliable starts. This system decreases the likelihood of pilot light issues and enhances safety, providing peace of mind for users. Additionally, the built-in safety features, including flame rollout switches and limit switches, help guard against overheating and system malfunctions.

Durability is another key characteristic of this heating unit. The VYGF33NRA features a rugged design with high-quality materials, ensuring it can withstand the rigors of daily use. Its compact footprint allows for flexible installation, enabling it to fit comfortably in tighter spaces without compromising on performance.

The Vanguard Heating VYGF33NRA also emphasizes ease of maintenance. It comes with accessible components that facilitate routine servicing and upkeep, thus prolonging the lifespan of the unit and enhancing its reliability.

Furthermore, it produces minimal noise during operation, contributing to a quieter indoor environment. This feature makes it an excellent choice for residential settings where comfort and tranquility are paramount.

In summary, the Vanguard Heating VYGF33NRA stands out for its impressive heating capacity, efficiency, advanced technologies, and durable construction. Designed for versatile applications, it offers users an effective and sustainable solution for their heating needs, making it a valuable addition to any space.