INSTALLATION

®

UNVENTED NATURAL GAS FIREPLACE

INSTALLATION

Continued

8.Tighten trim hanging screws (#10 x 6.25 shoulder) into holes in cabinets. Place the assembled trim onto fireplace cabinet. Align hanging notches on trim with hanging screws on side of fire- place (see Figure 7). Push trim firmly into place, sliding hanging notches over hanging screws.

Trim

Hanging

Screws

Hanging Notches on Trim

CONVENTIONAL FIREPLACE INSTALLATION Assembled

Brass Trim

Figure 7 - Attaching Brass Trim to Fireplace

INSTALLATION

CLEARANCES

Manual background WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Clearances For Side

Combustible Material, Side Wall,

and Ceiling

A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 8.

Example: The face of a mantel, book- shelf, etc. is made of combustible ma- terial and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 8).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

 

 

 

 

 

 

 

 

 

 

121/4

 

 

 

 

 

 

 

 

 

 

 

101/2

 

 

Example

 

 

 

 

 

 

8 3/4

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

INCHES

 

 

 

 

 

 

 

 

 

 

51/4

 

 

 

 

 

 

 

 

 

 

31/2

 

 

 

 

 

 

 

 

 

 

13/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8

 

 

 

 

 

 

 

 

 

 

 

7/16

 

FIREBOX

.5

1

2

4

6

8

10

12

14

16 *

 

 

 

 

 

INCHES

 

 

 

 

 

*Minimum 16 inches from Side Wall

Figure 8 - Minimum Clearance for Combustible to Wall

CONVENTIONAL FIREPLACE INSTALLATION

Conventional installation of this fireplace involves installing fireplace along with the corner, face, or cabinet mantel with hearth base accessories against a wall in your home. Follow the instructions below to install the fireplace in this manner.

Note: The instructions below show installa- tion using the cabinet mantel and the G3000F/G3001U/G3004W/G3006F/ G3007U series hearth base accessories. The hearth base accessory shown is optional for this installation. You can install fireplace and cabinet/corner mantel directly on the floor. The corner mantel accessory cannot be installed with the G3000F/G3001U/ G3004W/G3006F/G3007U hearth bases. The corner mantel can be paired with the G3008F/G3009U/G3010F corner hearth base. If mounting fireplace and cabinet or corner mantel to the floor, an optional G3005 Slim Base kit may be installed.

1.Assemble cabinet mantel, hearth base, and trim accessories. Assembly instruc- tions are included with each accessory.

2.When installing blower, install a prop- erly grounded, 120 volt three-prong electrical outlet at fireplace location if an outlet is not there. If possible, lo- cate outlet so cabinet mantel will cover it when installed (see Figure 9).

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Lo- cation, pages 10 and 11.

4.Place hearth base accessory against wall at installation location. Cut an ac- cess hole in hearth top to run gas line to fireplace (see Figure 9). Make sure to locate access hole so cabinet mantel will cover it when installed. Note: You can secure base to floor using wood screws. Countersink screw heads and putty over.

5.Route gas line through access hole in hearth base.

6.Center cabinet mantel on hearth base (see Figure 10). Make sure mantel is flush against wall.

7.Break off nailing flanges (see Figure 11, page 9) with hammer or pliers.

8.Place cardboard or other protective material on top of hearth base. Care- fully set fireplace on protective mate- rial, with back of fireplace inside man- tel opening.

9.If blower is installed, route blower elec- trical cord through access holes in ei- ther side of fireplace. Note: Bushing may be moved if necessary. Plug elec- trical cord into electrical outlet.

 

Flexible

Electrical

Gas Line

Hearth

Outlet

Access

Gas Line

Base

 

Hole

 

 

Figure 9 - Placing Hearth Base Accessory Against Wall

Cabinet

Mantel

Figure 10 - Installing Cabinet Mantel