OWNER’S MANUAL

AIR FOR

COMBUSTION AND

VENTILATION

Continued

DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION

Determining if You Have a Confined or Unconfined Space

Use this work sheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = _________________ cu. ft. (volume of space)

Example: Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free fireplace

 

___________________ Btu/Hr

 

 

 

 

Gas water heater*

 

___________________ Btu/Hr

 

 

 

 

Gas furnace

 

___________________ Btu/Hr

Example:

 

 

 

Vented gas heater

 

___________________ Btu/Hr

Gas water heater

 

40,000

Btu/Hr

Gas fireplace logs

 

___________________ Btu/Hr

Vent-free fireplace

+

33,000

Btu/Hr

Other gas appliances*

+

___________________ Btu/Hr

Total

=

73,000

Btu/Hr

Total

=

___________________ Btu/Hr

 

 

 

 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_____________ Btu/Hr (maximum the space can support)

_____________ Btu/Hr (actual amount of Btu/Hr used)

Example: 63,300 Btu/Hr (maximum the space can support) 73,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework work sheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 6.

B.Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 6.

C.Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes.

Continued

105269

5

Page 5
Image 5
Vanguard Heating VYGF33NRA AIR for Combustion Ventilation, Determining FRESH-AIR Flow for Fireplace Location

VYGF33NRA specifications

The Vanguard Heating VYGF33NRA is a highly efficient heating solution designed to provide reliable warmth for residential and commercial spaces. This natural gas-fired unit is known for its robust construction and advanced technology, ensuring it meets the needs of various applications while delivering optimal performance.

One of the standout features of the VYGF33NRA is its impressive heating capacity. With an output of 33,000 BTUs, this heater can effectively warm large areas, making it suitable for homes, workshops, and offices. It is particularly advantageous for spaces that demand consistent and reliable heating throughout colder months.

Efficiency is a hallmark of the Vanguard VYGF33NRA. It boasts a remarkable AFUE (Annual Fuel Utilization Efficiency) rating, which signifies its ability to convert a high percentage of gas into usable heat. This feature not only supports energy conservation but also helps reduce overall heating costs, making it an eco-friendly choice for consumers.

The VYGF33NRA is equipped with a state-of-the-art electronic ignition system, ensuring quick and reliable starts. This system decreases the likelihood of pilot light issues and enhances safety, providing peace of mind for users. Additionally, the built-in safety features, including flame rollout switches and limit switches, help guard against overheating and system malfunctions.

Durability is another key characteristic of this heating unit. The VYGF33NRA features a rugged design with high-quality materials, ensuring it can withstand the rigors of daily use. Its compact footprint allows for flexible installation, enabling it to fit comfortably in tighter spaces without compromising on performance.

The Vanguard Heating VYGF33NRA also emphasizes ease of maintenance. It comes with accessible components that facilitate routine servicing and upkeep, thus prolonging the lifespan of the unit and enhancing its reliability.

Furthermore, it produces minimal noise during operation, contributing to a quieter indoor environment. This feature makes it an excellent choice for residential settings where comfort and tranquility are paramount.

In summary, the Vanguard Heating VYGF33NRA stands out for its impressive heating capacity, efficiency, advanced technologies, and durable construction. Designed for versatile applications, it offers users an effective and sustainable solution for their heating needs, making it a valuable addition to any space.