SPECIFICATIONS
Btu (Variable)
Type Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (in. of water) * Maximum
Minimum
Dimensions, Inches (H x W x D)
Fireplace (including hood and screws)
Carton
Weight, pounds
Fireplace
Shipping
* For purposes of input adjustment
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
SPECIFICATIONS
SERVICE HINTS 23
TECHNICAL SERVICE
REPLACEMENT PARTS
VMH26TPB | VMH26TNB |
14,000/26,000 | 14,000/26,000 |
Propane/LP Only | Natural Only |
Piezo | Piezo |
8" W.C. | 3" W.C. |
14" | 10.5" |
11" | 5" |
25 7/8 x 26 13/16 x 9 3/8 | 25 7/8 x 26 13/16 x 9 3/8 |
32 5/8 x 27 3/16 x 11 5/8 | 32 5/8 x 27 3/16 x 11 5/8 |
44 1/2 lbs. | 44 1/2 lbs. |
48 lbs. | 48 lbs. |
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
•burner will have delayed ignition
•fireplace will not produce specified heat
•propane/LP gas supply may be low (propane/LP only)
You may feel your gas pressure is too low. If so, contact your local propane/LP or natural gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at
You can also visit DESA Heating Products’ technical services web site at www.desatech.com.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA Heating Products’ Techni- cal Service Department at
When calling DESA, have ready
•your name
•your address
•model and serial numbers of your fireplace
•how fireplace was malfunctioning
•type of gas used (propane/LP or natural gas)
•purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA Heating Products at
When calling DESA, have ready
•model number of your fireplace
•the replacement part number
For morevisit www..com