![CHECK GAS TYPE](/images/new-backgrounds/53142/5314215x1.webp)
8
INSTALLATION
Check Gas Type
Installation Items
Locating Fireplace
INSTALLATION
Continued
CAUTION: This fireplace creates warm air cur- rents. These currents move heat to wall surfaces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.
IMPORTANT:
Note: Your Vanguard fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.
Use the dimensions shown for rough openings to create the easiest installation (see
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.
INSTALLATION ITEMS
Before installing fireplace, make sure you have the items listed below.
•external regulator - propane/LP only (supplied by installer)
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection*
•ground joint union
•sediment trap
•tee joint
•pipe wrench
*A CSA
Note: If desired, purchase a
LOCATING FIREPLACE
WARNING: Maintain the minimum clearances shown in Figures 7 and 8. If you can, provide greater clearances from floor, ceiling, and joining wall.
You can recess firebox into the wall. You can also position fireplace in the optional cabinet or corner mantels. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual. Pur- chase the optional mantel from your dealer (see Accessories, page 26).
| CEILING |
| 36" |
| Minimum |
6" |
|
Minimum |
|
From |
|
Sides Of |
|
Fireplace |
|
Left | Right |
Side | Side |
0" Minimum To Top Surface
Of Carpeting, Tile Or Other
Combustible Material
FLOOR
Figure 7 - Mounting Clearances As Viewed From Front of Fireplace Shown
CEILING
Top Of
Mantel Can
Be Flush36"
Minimum
With Wall
| Right | |
Left | Side | |
0" Minimum To Top | ||
Side | ||
| Surface Of Carpeting, | |
| Tile Or Other | |
| Combustible Material |
Figure 8 - Mounting Clearances As Viewed From Front of Fireplace Shown with Optional Mantel
Note: When installing fireplace directly on carpeting, tile or other combustible material, other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth of the fireplace.
For
.