Vanguard Managed Solutions FLAME-MAX Installing Heater Base Assembly, Installation Items Needed

Models: FLAME-MAX

1 30
Download 30 pages 52.23 Kb
Page 10
Image 10
INSTALLING HEATER BASE ASSEMBLY

VANGUARD FLAME-MAX®

UNVENTED NATURAL GAS LOG HEATER

INSTALLATION

Continued

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Note: When used as a vented heater, appli- ance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of non combustible material.

If your heater is a manually controlled model, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode:

Damper

Damper

Clamp

Clamp

Damper

Damper

Masonry Fireplace

Manufactured Fireplace

Figure 10 - Attaching Damper Clamp

1.The fireplace does not meet the clear- ance to combustibles requirements for vent-free operation

2.State or local codes do not permit vent- free operation

3.You prefer vented operation

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 29). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Area of Various Standard

Round Flues

 

 

Diameter (ins.)

Area (sq. ins.)

 

 

 

5"

 

20 sq. inches

6"

 

29 sq. inches

7"

 

39 sq. inches

8"

 

51 sq. inches

 

 

 

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. ins.)

 

 

 

6' to 15'

 

39 sq. inches

15' to 30'

 

29 sq. inches

 

 

 

INSTALLING HEATER BASE ASSEMBLY

Installation Items Needed CAUTION: Do not remove the metal data plates attached to the heater base assembly. The data plates contain important warranty information.

Manual background WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

Manual background WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fire- place floor to allow access to heater control panel. This will in- sure adequate air flow and guard against sooting. Raise fireplace floor with noncombustible mate- rial. Make sure material is secure.

Manual background CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base assem- bly by grates.

IMPORTANT: Make sure the heater burner is level. If heater is not level, heater will not work properly.

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose (not provided) (if allowed by local codes)

sealant (resistant to propane/LP gas, not provided)

electric drill with 3/16" drill bit (metal or masonry as applicable)

flathead screwdriver

1.Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flex- ible gas hose to gas regulator of heater (see Figure 11, page 11).

IMPORTANT: Hold gas regulator with wrench when connecting flexible gas hose.

2.Locate two masonry screws in hard- ware package.

3.Place heater base in fireplace.

4.Place logs in their proper position on heater base.

5.Center heater base and logs front-to- back and side-to-side in fireplace.

6.Carefully remove logs without moving heater base.

7.Mark screw locations through one hole on each side of the mounting bracket (see Figure 12, page 11). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.

10

105187

Page 10
Image 10
Vanguard Managed Solutions FLAME-MAX Installing Heater Base Assembly, Installation Items Needed, Vanguard Flame-Max