Vanguard Managed Solutions FLAME-MAX Connecting To Gas Supply, Installation, Continued

Models: FLAME-MAX

1 30
Download 30 pages 52.23 Kb
Page 11
Image 11
CONNECTING TO GAS

OWNER’S MANUAL

INSTALLATION

Continued

8.Remove heater base from fireplace.

9.Drill holes at marked locations using 3/16" drill bit.

10.Attach base assembly to fireplace floor using two masonry screws (in hardware package).

11.Connect to gas supply. See Connect- ing To Gas Supply.

12.Replace logs on heater base.

Heater Gas

Regulator

Flexible Gas

Fitting

 

Hose (if allowed

 

by local codes)

 

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator

Vintage Oak

Log Chassis

Masonry Screw

Bracket with

Screw Holes

Golden Oak and

Birch Model Chassis

Masonry Screw

CONNECTING TO GAS

SUPPLY

NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

manual shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 29.

Manual background WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as well-head gas.

A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap*

From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

 

Tee

 

Sediment

Joint

 

Trap

Pipe

3" Minimum

 

Nipple

 

 

Cap

 

Figure 13 - Gas Connection

Manual background CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Manual backgroundCAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Manual background CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

Approved Flexible Gas Hose (if allowed by local codes)

Gas Regulator

Bracket with

Screw Holes

Figure 12 - Attaching Base Assembly to Fireplace Floor

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 29.

** Minimum inlet pressure for purpose of input adjustment.